Background and purpose

A novel O-ring gantry can deliver stereotactic body radiation therapy (SBRT) with artificial intelligence-facilitated, CT-guided online plan adaptation. It gates mobile targets by optically monitoring skin surface motion. However, this gating solution has not been clinically validated. We conducted a trial to evaluate the feasibility of optical skin surface-guided gating for patients with mobile upper abdominal or lower thoracic malignancies treated with SBRT on this platform (NCT05030454).

Materials and methods

Ten patients who were prescribed SBRT to a thoracic or abdominal target and were capable of breath-hold for at least 17 s enrolled. They received SBRT in five fractions with breath-hold technique and optical skin surface motion monitored-gating