Reliability, accuracy, and minimal detectable difference of a mixed concept marker set for finger kinematic evaluation.
Ontology highlight
ABSTRACT: The study of finger biomechanics requires special tools for accurately recording finger joint data. A marker set to evaluate finger postures during activities of daily living is needed to understand finger biomechanics in order to improve prosthesis design and clinical interventions. The purpose of this study was to evaluate the reliability of a proposed hand marker set (the Warwick marker set) to capture finger kinematics using motion capture. The marker set consisted of the application of two and three marker clusters to the fingers of twelve participants who participated in the tests across two sessions. Calibration markers were applied using a custom palpation technique. Each participant performed a series of range of motion movements and held a set of objects. Intra and inter-session