Immunofluorescence Staining for IgG Subclass: Cause for Discrepancy in the Detection of IgG1.


ABSTRACT:

Introduction

Immunofluorescence (IF) staining for IgG subclasses plays an important role in the classification of kidney disease. However, widely used IgG subclass-specific antibodies are now commercially unavailable. Thus, we compared alternative antibodies for performing IgG subclass staining.

Methods

A total of 21 cases were stained by 3 different methods: direct IF using fluorescein isothiocyanate (FITC)-conjugated polyclonal antibodies against IgG1-4 (commercially unavailable method), direct IF using FITC-conjugated monoclonal antibodies (clones HP-6091, 6014, 6050, and 6025), indirect IF using monoclonal antibodies (clones HP-6069, 6002, 6050, and 6025), and FITC-conjugated polyclonal secondary antibody. For cases with discrepancy in IgG1 staining, additional direct IF

SUBMITTER: Kudose S 

PROVIDER: S-EPMC10658247 | biostudies-literature | 2023 Nov

REPOSITORIES: biostudies-literature