Project description:BackgroundStructural valve dysfunction in bioprosthetic heart valves necessitates redo replacement procedure that are associated with high mortality and morbidity. The transcatheter valve-in-valve (VIV) approach has emerged as a preferred option for patients requiring redo procedures due to structural valve degeneration. We report from India the first case of the simultaneous transcatheter dual VIV implantation (mitral valve and tricuspid valves) in a high-surgical-risk patient.Case summaryA 57-year-old female was presented with a history of rheumatic heart disease, post-mitral valve as well as tricuspid valve replacement (perimount 33 mm) 11 years back. Bioprosthetic heart valve was chosen probably due to limited life expectancy and compliance issues with monitoring of international normalised ratio (INR). She now presented with progressive dyspnoea, oedema, and palpitations (New York Heart Association Class III) for the last 6 months. The patient was scheduled for transcatheter dual valve replacement simultaneously. The procedure was successful with a favourable outcome, short hospital stays, and early recovery.DiscussionThis is the first case of simultaneous transcatheter dual valve replacement reported from India, which is fluoroscopically guided and supported by TEE. It is a valuable and considerable option for patients with failing bioprosthesis valves who are at increased peri-operative risk.
Project description:BackgroundBesides transcatheter edge-to-edge repair (TEER), there are new interventional treatment options for mitral and tricuspid regurgitation in evaluation, such as a complete replacement of the valve through a prosthesis.Case summaryA 78-year-old previous coronary artery bypass graft-operated patient with symptomatic severe mitral regurgitation and tricuspid regurgitation was sequentially treated by a transfemoral transcatheter mitral and tricuspid valve prosthesis (Cardiovalve; Cardiovalve Ltd, Israel) due to unfavourable mitral valve anatomy. The transcatheter mitral valve implantation (TMVI) was performed first and after progression of the tricuspid regurgitation, a second transcatheter valve prosthesis was implanted in tricuspid position (TTVI) 1.5 years later. Imaging showed a twin look-alike picture of a mitral and tricuspid prosthesis and showing the possibility of a complete transcatheter based replacement of the mitral and tricuspid valve.DiscussionThis case shows the possibility of a Cardiovalve prosthesis being used for TMVI and TTVI in a single patient. Especially in TEER ineligible patients, it might be a good treatment option after device approval.
Project description:BackgroundTranscatheter mitral valve in ring procedure has emerged as a minimally invasive alternative to re-do surgery among patients with failed mitral annuloplasty rings. Uncommonly, haemolysis presents as a complication after the percutaneous valvular procedures and often require aggressive measures to correct paravalvular leaks and mechanical collision.Case summaryWe report a case of an 82-year-old female who underwent a transcatheter valve in ring procedure (Edwards Sapien S3, Edwards Lifesciences) for symptomatic severe mitral regurgitation from a bioprosthetic annuloplasty ring failure complicated by acute haemolytic anaemia a week after the procedure manifesting as dark coloured urine, profound icterus, and acute renal injury. She was treated with a post-dilation balloon valvuloplasty leading to reduction in haemolysis, but the patient was readmitted with acute haemolysis episode again. At this time, a decision was made to perform a repeat valve in valve TMVR with a 29 mm S3 Edwards Sapien valve which led to a resolution of haemolysis.DiscussionIn this case, the leaflets of previously placed S3 valve sealed the blood flow through the valve frame thus diverting the blood flow away from the area of collision leading to resolution of haemolysis.
Project description:BackgroundConcomitant structural degeneration of surgical mitral bioprostheses and paravalvular leak (PVL) is rare but potentially fatal. Data pertaining to simultaneous transcatheter mitral valve implantation (TMVI) and percutaneous PVL closure are limited, and the optimal treatment strategy remains undetermined. We report a case of simultaneous TMVI and double percutaneous PVL closure in a patient with a degenerated bioprosthetic mitral valve and associated medial and lateral PVLs.Case summaryA 75-year-old woman who underwent combined aortic (Edwards Perimount Magna 19 mm) and mitral (Edwards Perimount Magna 25 mm) surgical valve replacement 6 years ago was referred for treatment of new-onset orthopnoea and severely reduced exercise capacity. Transoesophageal echocardiography revealed severe mitral stenosis and concomitant moderate to severe mitral regurgitation, originating from two PVLs located medial and lateral from the surgical bioprosthesis. Due to high surgical risk, we performed successful transseptal mitral valve-in-valve (ViV) implantation combined with the closure of two PVLs during the same procedure.DiscussionAlthough surgery should be considered as a first-line treatment in this setting, most patients have extremely high or prohibitive surgical risk inherent to repeat open heart surgery. Mitral ViV implantation appears a reasonable treatment option for patients with failed mitral bioprostheses. Furthermore, a recent study of percutaneous PVL closure showed no significant difference in long-term all-cause mortality compared with redo open-heart surgery. Simultaneous TMVI and percutaneous PVL closure appears feasible in selected high-risk patients.
Project description:BackgroundModerate or severe tricuspid regurgitation (TR) recurs in up to one-third of patients within 8 years of surgical annuloplasty repair. Reoperation often carries high risk with poor outcomes. Transcatheter valve-in-ring repair is an emerging alternative treatment. However, residual regurgitation is frequent and may necessitate further procedures.Case summaryA 52-year-old female was diagnosed with severe rheumatic valvular heart disease. The patient underwent mechanical aortic and mitral valve replacement. Additionally, tricuspid repair was performed using a semi-rigid annuloplasty ring (28 mm Edwards Physio Tricuspid). Within 2 years, the patient developed recurrent, isolated severe symptomatic TR, with progressive right ventricular dilatation. The patient was considered prohibitive risk for redo surgery and unsuitable for cardiac transplantation. She underwent percutaneous valve-in-ring transcatheter heart valve (THV) implantation using a 29 mm Sapien S3 (Edwards Lifesciences, CA, USA) valve. Persistent severe residual para-ring TR warranted a further procedure to deploy vascular plugs, significantly reducing the TR to a mild jet with symptomatic improvement.DiscussionValve-in-ring THV implantation for failed surgical tricuspid annuloplasty repair is a rare procedure reserved for symptomatic patients at high or prohibitive risk for reoperation. Significant residual TR is a commonly encountered problem with incomplete annuloplasty rings following valve-in-ring procedures and may occur either intra-ring between the THV and the ring or para-ring. Implantation of vascular occlusion devices can be used to successfully treat residual TR at either location with good outcomes at 6-month follow-up. Further work is required to determine the longevity of this treatment.
Project description:BackgroundMitral annular calcification (MAC) is characterized by severe calcification of mitral annulus and might be associated with both mitral regurgitation and stenosis. It is technically challenging for both surgical and percutaneous approach and is burdened by high mortality.Case summaryThe present case report describes a complex case of mitral steno-insufficiency (baseline transvalvular gradient = 5 mmHg, effective regurgitant orifice area 0.45 cm2, vena contracta 0.8 cm), due to MAC in an 83-year-old lady. In consideration of the clinical context (MAC) and patient's several comorbidities and history of previous surgical interventions, she was deemed not suitable for surgery and a percutaneous treatment was selected (valve-in-MAC). Due to significant paravalvular leak, further implantation of a plug was required.ConclusionThe MAC represents a clinical and technical challenge for surgery. Transcatheter mitral valve implantation in MAC is a feasible alternative although it is technically challenging and burdened by high mortality. Detailed procedural planning is of utmost importance to achieve successful outcomes.
Project description:BackgroundGerbode defect is a congenital or acquired communication between the left ventricle and right atrium. While the defect is becoming a more well-recognized complication of cardiac surgery, it presents a diagnostic and therapeutic challenge for providers. This case highlights the predisposing factors and imaging features that may assist in the diagnosis of Gerbode defect, as well as potential approaches to treatment.Case summaryWe report a patient with severe mitral stenosis as a result of remote mediastinal radiation who underwent extensive decalcification during surgical mitral valve replacement and tricuspid valve repair. Following the procedure, he developed progressive heart failure refractory to medical management. Extensive workup ultimately led to the diagnosis of iatrogenic acquired Gerbode defect. Close collaboration between adult cardiology, cardiothoracic surgery, and the congenital cardiology services led to an optimal treatment plan involving percutaneous closure of the defect.DiscussionGerbode defect is a rare complication of invasive procedures involving the interventricular septum or its nearby structures. An understanding of the key echocardiographic features will aid providers in timely diagnosis. Percutaneous repair should be strongly considered for patients who may be poor surgical candidates.
Project description:BackgroundTranscatheter valve-in-valve replacement (TMViVR) is an alternative option for patients with bioprosthetic valve failure (BVF) who are at high surgical risk. Although infective endocarditis (IE) after transcatheter mitral valve-in-valve replacement is unusual, it is associated with significantly high mortality.Case presentationAn 81-year-old male patient was admitted with intermittent thoracic tightness, chest pain persisting for 3 years, and shortness of breath with nausea for 1 week. Two months prior, he received transcatheter mitral valve-in-valve replacement for recurrent heart failure and severe prosthetic mitral regurgitation. He developed a fever in the early postoperative period after TMViVR, with Staphylococcus lugdunensis bacteremia detected. He was discharged from the hospital after the blood culture turned negative following antibiotic treatment. During this hospitalization, prosthetic valve endocarditis was confirmed, resulting in severe prosthetic mitral stenosis and severe pulmonary hypertension. Blood cultures identified Staphylococcus lugdunensis again. Despite anti-infective therapy, the patient succumbed to complications from his complex medical history and comorbidities.ConclusionsWhile transcatheter valve implantation provides an alternative option for dealing with valvular disease, prosthetic valve endocarditis (PVE) as an unusual but catastrophic complication with poor prognosis should be taken seriously. Early detection through echocardiography, especially in high-risk patients presenting with suspicious symptoms, is crucial for timely intervention. Additionally, an appropriate perioperative antibiotic regimen is essential to prevent infection and improve prognosis.
Project description:BackgroundAnnuloplasty failure caused by ring dehiscence can lead to trans-ring and para-ring mitral regurgitation (MR). Transcatheter treatments are available for patients at prohibitive risk of surgery. In patients unsuitable for edge-to-edge repair, valve-in-ring (ViR) transcatheter mitral valve (MV) implantation has been described to treat trans-ring or para-ring jets but not both concurrently.Case summaryA 78-year-old male presented with severe MR due to dehiscence of a 34 mm Edwards Physio II mitral annuloplasty ring. Transoesophageal echocardiography showed two jets of regurgitation; trans-ring and para-ring. Repair was successfully undertaken with a ViR procedure (29 mm S3 Edwards Lifesciences).DiscussionPatients with failure of MV annuloplasty with trans-ring and para-ring regurgitation can be safely and effectively treated by ViR transcatheter MV implantation.
Project description:Para mitral annular ring leakage can occur following ring dehiscence after mitral annuloplasty. Percutaneous device closure of para-annular ring leakage can be performed successfully to treat such regurgitations with good transesophageal echocardiography guidance and patient selection. While para valvular device closure has been described in the medical literature, there have been few anecdotal reports published on para ring leak device closures. In this case, we highlight our experience from the successful closure of a para mitral annular ring closure with an AVP III device. The patient had a para annular ring regurgitation post coronary artery bypass grafting with mitral ring annuloplasty presenting with hemolytic anemia and acute renal failure, successfully treated by percutaneous device closure.Learning objectiveThis report describes the safety and effectiveness of a transcatheter para ring leak closure with an AVP III device. We applied the principles of device closure of paravalvular leak from our experience and related data from literature for this case and describe various hardware and techniques used for a successful closure of a para mitral ring leak.