Project description:Functional tests such as Motor Function Measure-32 (MFM-32), supine to stand, ascend/descend stairs permit the assessment of task-specific motor function in neuromuscular disease (NMD). The 6-min walk test (6MWT), though functional, is primarily used to assess endurance and disease progression in children with neuromuscular disorders. Barriers to 6MWT administration, in this population, can include reduced attention span due to age and inability to tolerate test length due to weakness. We propose task-specific functional deficits are related to endurance. Additionally, the 2-min walk test (2MWT) could effectively replace the 6MWT in this population. Seventy-seven participants, ages 5-18, with a variety of neuromuscular disorders performed the 6MWT, timed functional tests (TFT), and the MFM-32. Correlation and paired t-test analyses were used to compare the distance walked in the first 2 min (2MWD) to the distance walked in the entire 6 min (6MWD) and to the functional outcome measures above. The 2MWD strongly correlated with 6MWD and the other outcome measures. Paired t-test analysis also showed that the 2MWD did not differ from the distance walked in the last 2 min of the 6MWT. Although equivalence testing could not reject the claim that this difference exceeded the upper practical limit of 9.5 m, it only showed a modest overestimation of the 4-6MWD compared with the 2MWD. Together, our results support the ability of the 2MWD to predict the 6MWD, specifically in the pediatric neuromuscular disease population.
Project description:Heart rate recovery in 1 minute (HRR1) after the end of the 6-minute walk test (6MWT) is a non-invasive method of determining autonomic dysfunction. This parameter remains largely unexplored in pulmonary arterial hypertension (PAH) registries. We aimed to define the cut-off value and accuracy for abnormal HRR1 after the 6MWT and to investigate the association between HRR1 and clinical worsening in patients with PAH. This composite outcome was defined as first occurrence of all-cause death OR hospitalization from any cause OR disease progression characterized by decreased ≥ 15% in six-minute walking distance from baseline AND start of new specific PAH treatment or persistent worsening of World Health Organization functional class (WHO-FC). We performed a prospective cohort study that included 102 consecutive patients with PAH confirmed by right heart catheterization that underwent an 6MWT upon the diagnosis, recruited from September 2004 to April 2020 and followed up until April 2021 or death. The median HRR1 was 18 beats (IQR: 10-22), 50 and 52 PAH patients with <18 beats and ≥18 beats, respectively. The best cut-off for HRR1 to discriminate clinical worsening was 17 beats, with area under the curve (AUC) of 0.704 (95%CI: 0.584-0.824). The internal validation model by bootstrap showed an AUC of 0.676 (95%CI: 0.566-0.786) and the most accurate value was obtained in the seventh year of follow-up (AUC = 0.711; 95%CI: 0.596-0.844). Patients with an HRR1 <18 beats at baseline had a median event-free time of 2.17 years (95%CI: 1.82 to 2.52) versus 4.75 years (95%CI: 1.43 to 8.07) from those with ≥18 beats. In conclusion, a HRR1 value of less than 18 beats may be a reliable indicator of poor prognosis in patients with PAH.
Project description:Wearable sensors are becoming increasingly popular for complementing classical clinical assessments of gait deficits. The aim of this review is to examine the existing knowledge by systematically reviewing a large number of papers focusing on the use of wearable inertial sensors for the assessment of gait during the 6-minute walk test (6MWT), a widely recognized, simple, non-invasive, low-cost and reproducible exercise test. After a systematic search on PubMed and Scopus databases, two raters evaluated the quality of 28 full-text articles. Then, the available knowledge was summarized regarding study design, subjects enrolled (number of patients and pathological condition, if any, age, male/female ratio), sensor characteristics (type, number, sampling frequency, range) and body placement, 6MWT protocol and extracted parameters. Results were critically discussed to suggest future directions for the use of inertial sensor devices in the clinics.
Project description:ObjectiveThe 6-minute walk test is widely used to assess functional status in neurological disorders. However, the test is subject to great inter-test variability due to fluctuating motivation, fatigue and learning effects. We investigated whether inter-test variability of the 6MWT can be reduced by heart rate correction.MethodsSixteen patients with neuromuscular diseases, including Facioscapulohumeral muscular dystrophy, Limb-girdle muscular dystrophy, Charcot-Marie-Tooths, Dystrophia Myotonica and Congenital Myopathy and 12 healthy subjects were studied. Patients were excluded if they had cardiac arrhythmias, if they received drug treatment for hypertension or any other medical conditions that could interfere with the interpretation of the heart rate and walking capability. All completed three 6-minute walk tests on three different test-days. Heart rate was measured continuously.ResultsSuccessive standard 6-minute walk tests showed considerable learning effects between Tests 1 and 2 (4.9%; P = 0.026), and Tests 2 and 3 (4.5%; P = 0.020) in patients. The same was seen in controls between Tests 1 and 2 (8.1%; P = 0.039)). Heart rate correction abolished this learning effect.ConclusionA modified 6-minute walk test, by correcting walking distance with average heart rate during walking, decreases the variability among repeated 6-minute walk tests, and should be considered as an alternative outcome measure to the standard 6-minute walk test in future clinical follow-up and treatment trials.
Project description:ObjectiveTo examine the association between 6-min walk test (6 MWT) performance and all-cause mortality, coronary heart disease mortality, and incident coronary heart disease in older adults.MethodWe conducted a time-to-event analysis of 1,665 Cardiovascular Health Study participants without prevalent cardiovascular disease with a 6 MWT.ResultsDuring a mean follow-up of 8 years, there were 305 incident coronary heart disease events, and 504 deaths of which 100 were coronary heart disease-related deaths. The 6 MWT performance in the shortest two distance quintiles was associated with increased risk of all-cause mortality (290-338 m: hazard ratio [HR] = 1.7; 95% confidence interval [CI] = [1.2, 2.5]; <290 m: HR = 2.1; 95% CI = [1.4, 3.0]). The adjusted risk of coronary heart disease mortality incident events among those with a 6 MWT < 290 m was not significant.DiscussionPerformance on the 6 MWT is independently associated with all-cause mortality and is of prognostic utility in community-dwelling older adults.
Project description:Although the 6 min walk test (6MWT) is well-established for assessing desaturation in patients with interstitial lung disease (ILD), it cannot be easily performed in primary healthcare settings. This retrospective observational study aimed to evaluate the usefulness of the 1 min sit-to-stand test (1STST) for assessing desaturation during 6MWT in ILD patients with normal resting blood oxygen levels. We included 116 patients, and the pulse oxygen saturation (SpO2) for both methods was analyzed. The SpO2 nadir during the 1STST and 6MWT correlated strongly (ρ = 0.82). The frequency of patients with nadir SpO2 < 90% was consistent for both tests (κ = 0.82). 1STST was superior to diffusing capacity for carbon monoxide in detecting desaturation during the 6MWT. These findings were similarly stratified according to performance status or dyspnea scale. The 1STST can easily measure exertional desaturation in ILD patients with normal resting blood oxygen levels and is an alternative to the 6MWT.
Project description:Background and objectiveAlthough the six-minute walk test (6MWT) is widely used as a measure of exercise capacity, it may not be applicable in some settings and populations. This issue has led to increased use of the two-minute walk test (2MWT) to assess exercise capacity. The main objective of this study is to establish reference equations for the two-minute walk distance (2MWD) in healthy Chinese adults aged 18-85 years.MethodsA total of 973 volunteers took part in the study. We obtained verbal consent from all participants before the test, and the study design was approved by the ethics committees of Wenzhou People's Hospital. The participants performed two 2MWTs using a standardized protocol, and the longer distance was used for further analysis. Stepwise multiple regression analysis was performed using age, height and weight as independent variables and was used to establish the reference equations for the 2MWD in the male and female groups.ResultsThe mean walking distance for all participants was 199.1±25.81 m. Age and height were identified as independent factors that influenced the 2MWD, and they explained 35% and 34% of the variance in distance for the male and female groups, respectively.ConclusionThis study resulted in determination of reference equations for predicting the 2MWD in healthy Chinese adults. These 2MWD standards will provide useful references for medical care in some settings and populations.
Project description:BackgroundIn spinal muscular atrophy (SMA), weakness, decreased endurance, and fatigue limit mobility. Scales have been developed to measure function across the wide spectrum of disease severity. However, these scales typically are observer dependent, and scores are based on sums across Likert-scaled items. The Six-Minute Walk Test (6MWT) is an objective, easily administered, and standardized evaluation of functional exercise capacity that has been proven reliable in other neurologic disorders and in children.MethodsTo study the performance of the 6MWT in SMA, 18 ambulatory participants were evaluated in a cross-sectional study. Clinical measures were 6MWT, 10-m walk/run, Hammersmith Functional Motor Scale-Expanded (HFMSE), forced vital capacity, and handheld dynamometry. Associations between the 6MWT total distance and other outcomes were analyzed using Spearman correlation coefficients. A paired t test was used to compare the mean distance walked in the first and sixth minutes.ResultsThe 6MWT was associated with the HFMSE score (r = 0.83, p < 0.0001), 10-m walk/run (r = -0.87, p < 0.0001), and knee flexor strength (r = 0.62, p = 0.01). Gait velocity decreased during successive minutes in nearly all participants. The average first minute distance (57.5 m) was significantly more than the sixth minute distance (48 m) (p = 0.0003).ConclusionThe Six-Minute Walk Test (6MWT) can be safely performed in ambulatory patients with spinal muscular atrophy (SMA), correlates with established outcome measures, and is sensitive to fatigue-related changes. The 6MWT is a promising candidate outcome measure for clinical trials in ambulatory subjects with SMA.
Project description:ObjectivesWe aimed to assess the validity of the six-minute walk test (6MWT) to reflect the functional capacity of children with congenital heart disease (CHD), evaluate a possible correlation between the 6MWT distance with cardiopulmonary exercise test (CPET) variables, as well as to find a cutoff value to stratification the physical fitness in this population.MethodsWe enrolled 459 children with CHD, 6-18 years old, who performed a complete CPET and 6MWT on the same day in a cross-sectional observational study. Correlations between variables of CPET and six-minute walking distance (6MWD) were analyzed and cutoff values of 6MWD were identified for the classification of the physical fitness in the population.ResultsThe mean distance ambulated during the 6MWT was 578 ± 65 m, 590 ± 65 m for boys, and 562 ± 62 m for girls (p < 0.001). Both VO2max and %predicted VO2max showed a correlation with the 6MWT distance (r = 0.35, p < 0.001 and r = 0.51, p < 0.001, respectively), and an inverse correlation was found between VE/VCO2 slope and the 6MWT distance (r = -0.31; p < 0.001). There appeared to be a linear association between 6MWD and VO2max up to a 6MWD of approximately 600 m. We divided the population into 4 subgroups (boys <130 cm; boys ≥130 cm; girls <130 cm; girls ≥130 cm), and get the cutoff values (554 m, 617 m, 549 m, 587 m) respectively equivalent to 80% of predicted VO2max. The 6MWT distances of another 102 patients were applied for external verification of the cutoff values.ConclusionsOur study provided evidence on when a 6MWT should be considered as a convincing complementary test in the pediatric population with CHD and explored the classification of exercise tolerance using a 6MWD value. The cut-off values for 6MWD may be qualified as an intervention target for exercise rehabilitation.