Unknown

Dataset Information

Exponential dosing to standardize myocardial perfusion image quality with rubidium-82 PET.


ABSTRACT:

Background

82Rb PET is commonly performed using the same injected activity in all patients, resulting in lower image quality in larger patients. This study compared 82Rb dosing with exponential vs proportional functions of body weight on the standardization of myocardial perfusion image (MPI) quality.

Methods

Two sequential cohorts of N = 60 patients were matched by patient weight. Rest and dipyridamole stress 82Rb PET was performed using 0.1 MBq·kg-2 exponential and 9 MBq·kg-1 proportional dosing. MPI scans were compared qualitatively with visual image quality scoring (IQS) and quantitatively using the myocardium-to-blood contrast-to-noise ratio (CNR) and blood background signal-to-noise ratio (SNR) as a function of bod

SUBMITTER: Tavoosi A 

PROVIDER: S-EPMC10682245 | biostudies-literature | 2023 Dec

REPOSITORIES: biostudies-literature