Ventricular tachycardia and in-hospital mortality in the intensive care unit.


ABSTRACT:

Background

Continuous electrocardiographic (ECG) monitoring is used to identify ventricular tachycardia (VT), but false alarms occur frequently.

Objective

The purpose of this study was to assess the rate of 30-day in-hospital mortality associated with VT alerts generated from bedside ECG monitors to those from a new algorithm among intensive care unit (ICU) patients.

Methods

We conducted a retrospective cohort study in consecutive adult ICU patients at an urban academic medical center and compared current bedside monitor VT alerts, VT alerts from a new-unannotated algorithm, and true-annotated VT. We used survival analysis to explore the association between VT alerts and mortality.

Results

We included 5679 ICU admissions (mean age 58 ± 17 years; 48% women), 503

SUBMITTER: Prasad PA 

PROVIDER: S-EPMC10685163 | biostudies-literature | 2023 Nov