Numerical simulation and experimental investigation of bubble behaviour during pool boiling in the coiled wire.


ABSTRACT: Under the computational fluid dynamics (CFD) framework, an interface tracking method has been used to perform several multiple simulations of coiled wire boiling in a pool. This study includes simulations of the boiling regime, including the Critical Heat Flux (CHF), ranging from nucleate boiling to film boiling. The purpose of this research was to investigate using coiled wire to increase the rate of heat transfer under constant heat flux conditions. The range of the applied heat flux is 130-1075 kW/m2. This research delves into the formation of bubble shapes, bubble diameter, and bubble departure frequency. The vapour bubble grows in size as the heat flux increases; with a heat flux of q'' = 600 kW/m2, it reaches its maximum measured diameter of about 9 mm. Addition

SUBMITTER: Jalali A 

PROVIDER: S-EPMC10685380 | biostudies-literature | 2023 Nov