Ontology highlight
ABSTRACT: Background
In the prospective, multicentre, randomised TARGET All Comers study, percutaneous coronary intervention (PCI) with the FIREHAWK biodegradable-polymer sirolimus-eluting stent (BP-SES) was non-inferior to the durable-polymer everolimus-eluting stent (DP-EES) for the primary endpoint of target lesion failure (TLF) at 12 months.Aims
We aimed to report the final study outcomes at 5 years.Methods
Patients referred for PCI were randomised to receive either a BP-SES or DP-EES in a 1:1 ratio in 10 European countries. Randomisation was stratified by centre and ST-elevation myocardial infarction (STEMI) presentation, and clinical follow-up extended to 5 years. The primary endpoint was TLF (composite of cardiac death, target vessel myocardial infarction [MI], or isch
SUBMITTER: Lansky AJ
PROVIDER: S-EPMC10687649 | biostudies-literature | 2023 Dec
REPOSITORIES: biostudies-literature