Transforming medical device biofilm control with surface treatment using microfabrication techniques.


ABSTRACT: Biofilm deposition on indwelling medical devices and implanted biomaterials is frequently attributed to the prevalence of resistant infections in humans. Further, the nature of persistent infections is widely believed to have a biofilm etiology. In this study, the wettability of commercially available indwelling medical devices was explored for the first time, and its effect on the formation of biofilm was determined in vitro. Surprisingly, all tested indwelling devices were found to be hydrophilic, with surface water contact angles ranging from 60° to 75°. First, we established a thriving Candida albicans biofilm growth at 24 hours. in YEPD at 30°C and 37°C plus serum in vitro at Cyclic olefin copolymer (COC) modified surface, which was subsequently confirmed via scanning electron microsc

SUBMITTER: Al Bataineh MT 

PROVIDER: S-EPMC10688649 | biostudies-literature | 2023

REPOSITORIES: biostudies-literature