ABSTRACT: Study design
Cross-sectional.Objectives
To investigate test-retest reliability of heart rate variability (HRV) metrics in SCI without restriction of activity over long (24-h) and shorter durations (5-min, 10-min, 1-h, 3-h and 6-h).Settings
University hospital in Khon Kaen, Thailand.Methods
Forty-five participants (11 with tetraplegia and 34 with paraplegia) underwent two 24-h recordings of RR-intervals to derive time and frequency HRV metrics. Relative reliability was assessed by intraclass correlation coefficient (ICC) and absolute reliability by coefficient of variation (CV) and Bland-Altman limits of agreement (LoA).Results
For 5- and 10-min durations, eight of eleven HRV metrics had moderate to excellent reliability (ICC 0.40-0.76); the remaining
SUBMITTER: Ruangsuphaphichat A
PROVIDER: S-EPMC10691965 | biostudies-literature | 2023 Dec