Intra-pocket ultrasound-guided axillary vein puncture vs. cephalic vein cutdown for cardiac electronic device implantation: the ACCESS trial.


ABSTRACT:

Background and aims

Intra-pocket ultrasound-guided axillary vein puncture (IPUS-AVP) for venous access in implantation of transvenous cardiac implantable electronic devices (CIED) is uncommon due to the lack of clinical evidence supporting this technique. This study investigated the efficacy and early complications of IPUS-AVP compared to the standard method using cephalic vein cutdown (CVC) for CIED implantation.

Methods

ACCESS was an investigator-led, interventional, randomized (1:1 ratio), monocentric, controlled superiority trial. A total of 200 patients undergoing CIED implantation were randomized to IPUS-AVP (n = 101) or CVC (n = 99) as a first assigned route. The primary endpoint was the success rate of insertion of all leads using the first assigned venous access tec