Unknown

Dataset Information

Evaluation of the Performance of Three Biomarker Assays for Recent HIV Infection Using a Well-Characterized HIV-1 Subtype C Incidence Cohort.


ABSTRACT: Biomarkers for detecting early HIV infection and estimating HIV incidence should minimize false-recent rates (FRRs) while maximizing mean duration of recent infection (MDRI). We compared HIV subtypes B, E and D (BED) capture enzyme immunoassay (BED), Sedia limiting antigen (LAg) avidity enzyme immunoassay, and Bio-Rad avidity incidence (BRAI) assays using samples from Zimbabwean postpartum women infected with clade C HIV. We calculated MDRIs using 590 samples from 351 seroconverting postpartum women, and FRRs using samples from 2,825 women known to be HIV positive for >12 months. Antibody kinetics were more predictable with LAg and had higher precision compared with BED or BRAI. BRAI also exhibited more variability, and avidity reversal in some cases. For BED, LAg, and BRAI, used alone or

SUBMITTER: Gonese E 

PROVIDER: S-EPMC10719552 | biostudies-literature | 2019 Jul

REPOSITORIES: biostudies-literature