Unknown

Dataset Information

The degree of permanent pacemaker dependence and clinical outcomes following transcatheter aortic valve implantation: implications for procedural technique.


ABSTRACT:

Aims

Conduction abnormalities necessitating permanent pacemaker (PPM) implantation remain the most frequent complication post-transcatheter aortic valve implantation (TAVI), yet reliance on PPM function varies. We evaluated the association of right-ventricular (RV)-stimulation rate post-TAVI with 1-year major adverse cardiovascular events (MACE) (all-cause mortality and heart failure hospitalization).

Methods and results

This retrospective cohort study of patients undergoing TAVI in two high-volume centers included patients with existing PPM pre-TAVI or new PPM post-TAVI. There was a bimodal distribution of RV-stimulation rates stratifying patients into two groups of either low [≤10%: 1.0 (0.0, 3.6)] or high [>10%: 96.0 (54.0, 99.9)] RV-stimulation rate post-TAVI. Hazard rat

SUBMITTER: Dykun I 

PROVIDER: S-EPMC10721444 | biostudies-literature | 2023 Nov

REPOSITORIES: biostudies-literature