Lung tissue injury and hemodynamic effects of ventilations synchronized or unsynchronized to continuous chest compressions in a porcine cardiac arrest model.


ABSTRACT:

Aim

Compare lung injury and hemodynamic effects in synchronized ventilations (between two chest compressions) vs. unsynchronized ventilations during cardiopulmonary resuscitation (CPR) in a porcine model of cardiac arrest.

Methods

Twenty pigs were randomized to either synchronized or unsynchronized group. Ventricular fibrillation was induced electrically and left for 1.5 minutes. Four minutes of basic chest compression:ventilation (30:2) CPR was followed by eight minutes of either synchronized or unsynchronized ventilations (10/min) during continuous compressions before defibrillation was attempted. Aortic, right atrial and intracerebral pressures, carotid and cerebral blood flow and cardiac output were measured. Airway monitoring included capnography and respiratory functio

SUBMITTER: Olasveengen TM 

PROVIDER: S-EPMC10753078 | biostudies-literature | 2024 Mar