Unknown

Dataset Information

0

Everything but the Kitchen Sink: An Analysis of Bacterial and Chemical Contaminants Found in Syringe Residue From People Who Inject Drugs.


ABSTRACT:

Background

People who inject drugs (PWID) are at high risk of severe wounds, invasive infections, and overdoses. To date, there are few data on the bacterial and chemical contaminants PWID are exposed to when using illicitly manufactured fentanyls and stimulants.

Methods

Previously used injection drug use equipment was recovered in St Louis, Missouri, by harm reduction organizations over a 12-month period. Syringe residue was analyzed for bacterial contaminants by routine culturing followed by whole genome sequencing of single bacterial isolates. Chemical adulterants in syringe residue were identified by liquid chromatography-mass spectrometry.

Results

Bacteria were cultured from 58.75% of 160 syringes analyzed. Polymicrobial growth was common and was observed in 23.75% of samples. Bacillus cereus was the most common pathogen present and was observed in 20.6% of syringe residues, followed closely by Staphylococcus aureus at 18.8%. One hundred syringes underwent mass spectrometry, which demonstrated that chemical adulterants were common and included caffeine, diphenhydramine, lidocaine, quinine, and xylazine.

Conclusions

Analysis of syringe residue from discarded drug use equipment demonstrates both chemical and biological contaminants, including medically important pathogens and adulterants.

SUBMITTER: Wildenthal JA 

PROVIDER: S-EPMC10766411 | biostudies-literature | 2024 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Everything but the Kitchen Sink: An Analysis of Bacterial and Chemical Contaminants Found in Syringe Residue From People Who Inject Drugs.

Wildenthal John A JA   Schwartz Drew J DJ   Nolan Nathanial S NS   Zhao Lingxia L   Robinson John I JI   Jones Erin E   Jawa Raagini R   Henderson Jeffrey P JP   Marks Laura R LR  

Open forum infectious diseases 20231211 1


<h4>Background</h4>People who inject drugs (PWID) are at high risk of severe wounds, invasive infections, and overdoses. To date, there are few data on the bacterial and chemical contaminants PWID are exposed to when using illicitly manufactured fentanyls and stimulants.<h4>Methods</h4>Previously used injection drug use equipment was recovered in St Louis, Missouri, by harm reduction organizations over a 12-month period. Syringe residue was analyzed for bacterial contaminants by routine culturin  ...[more]

Similar Datasets

| S-EPMC10980258 | biostudies-literature
| S-EPMC7302981 | biostudies-literature
| S-EPMC5493098 | biostudies-other
| S-EPMC7161982 | biostudies-literature
| S-EPMC5387338 | biostudies-literature
| S-EPMC10283252 | biostudies-literature
| S-EPMC10967053 | biostudies-literature
| S-EPMC7878321 | biostudies-literature
| S-EPMC9081164 | biostudies-literature
| S-EPMC10601138 | biostudies-literature