Combination of high resolution MRI with 3D-printed needle guides for ex vivo myocardial biopsies.
Ontology highlight
ABSTRACT: Magnetic resonance imaging (MRI) provides a multitude of techniques to detect and characterize myocardial infarction. To correlate MRI findings with histology, in most cases terminal animal studies are performed; however, precise extraction and spatial correlation of myocardial tissue samples to MRI image data is difficult. In this proof of concept study, we present a 3D-printing technique to facilitate the extraction of tissue samples from myocardial regions. Initially, seven pig hearts embedded in formaldehyde were imaged on a clinical 3 T system to define biopsy targets on high resolution ex vivo images. Magnitude images and R2*-maps acquired with a 3D multi-echo gradient echo sequence and 0.58 mm isotropic resolution were used to create digital models of the cardiac anatomy. Biopsy gui
SUBMITTER: Reiss S
PROVIDER: S-EPMC10770147 | biostudies-literature | 2024 Jan
REPOSITORIES: biostudies-literature
ACCESS DATA