High-Throughput Microbore LC-MS Lipidomics to Investigate APOE Phenotypes.


ABSTRACT: Microflow liquid chromatography interfaced with mass spectrometry (μLC-MS/MS) is increasingly applied for high-throughput profiling of biological samples and has been proven to have an acceptable trade-off between sensitivity and reproducibility. However, lipidomics applications are scarce. We optimized a μLC-MS/MS system utilizing a 1 mm inner diameter × 100 mm column coupled to a triple quadrupole mass spectrometer to establish a sensitive, high-throughput, and robust single-shot lipidomics workflow. Compared to conventional lipidomics methods, we achieve a ∼4-fold increase in response, facilitating quantification of 351 lipid species from a single iPSC-derived cerebral organoid during a 15 min LC-MS analysis. Consecutively, we injected 303 samples over ∼75 h to prove the robustness and reproducibility of the microflow separation. As a proof of concept, μLC-MS/MS analysis of Alzheimer's disease patient-derived iPSC cerebral organoid reveals differential lipid metabolism depending on APOE phenotype (E3/3 vs E4/4). Microflow separation proves to be an environmentally friendly and cost-effective method as it reduces the consumption of harmful solvents. Also, the data demonstrate robust, in-depth, high-throughput performance to enable routine clinical or biomedical applications.

SUBMITTER: Gadara D 

PROVIDER: S-EPMC10782415 | biostudies-literature | 2024 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

High-Throughput Microbore LC-MS Lipidomics to Investigate APOE Phenotypes.

Gadara Darshak D   Berka Vratislav V   Spacil Zdenek Z  

Analytical chemistry 20231219 1


Microflow liquid chromatography interfaced with mass spectrometry (μLC-MS/MS) is increasingly applied for high-throughput profiling of biological samples and has been proven to have an acceptable trade-off between sensitivity and reproducibility. However, lipidomics applications are scarce. We optimized a μLC-MS/MS system utilizing a 1 mm inner diameter × 100 mm column coupled to a triple quadrupole mass spectrometer to establish a sensitive, high-throughput, and robust single-shot lipidomics wo  ...[more]

Similar Datasets

| S-EPMC1436036 | biostudies-literature
| S-EPMC9563341 | biostudies-literature
| S-EPMC3005372 | biostudies-literature
| S-EPMC7407148 | biostudies-literature
| S-EPMC11579186 | biostudies-literature
| S-EPMC11354784 | biostudies-literature
| S-EPMC10753523 | biostudies-literature
| S-EPMC9127697 | biostudies-literature
| S-EPMC10408177 | biostudies-literature
| S-EPMC5421409 | biostudies-literature