Unknown

Dataset Information

0

Bimetallic Nanocatalysts Immobilized in Nanoporous Hydrogels for Long-Term Robust Continuous Glucose Monitoring of Smart Contact Lens.


ABSTRACT: Smart contact lenses for continuous glucose monitoring (CGM) have great potential for huge clinical impact. To date, their development has been limited by challenges in accurate detection of glucose without hysteresis for tear glucose monitoring to track the blood glucose levels. Here, long-term robust CGM in diabetic rabbits is demonstrated by using bimetallic nanocatalysts immobilized in nanoporous hydrogels in smart contact lenses. After redox reaction of glucose oxidase, the nanocatalysts facilitate rapid decomposition of hydrogen peroxide and nanoparticle-mediated charge transfer with drastically improved diffusion via rapid swelling of nanoporous hydrogels. The ocular glucose sensors result in high sensitivity, fast response time, low detection limit, low hysteresis, and rapid sensor warming-up time. In diabetic rabbits, smart contact lens can detect tear glucose levels consistent with blood glucose levels measured by a glucometer and a CGM device, reflecting rapid concentration changes without hysteresis. The CGM in a human demonstrates the feasibility of smart contact lenses for further clinical applications.

SUBMITTER: Kim SK 

PROVIDER: S-EPMC10782562 | biostudies-literature | 2022 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Bimetallic Nanocatalysts Immobilized in Nanoporous Hydrogels for Long-Term Robust Continuous Glucose Monitoring of Smart Contact Lens.

Kim Su-Kyoung SK   Lee Geon-Hui GH   Jeon Cheonhoo C   Han Hye Hyeon HH   Kim Seong-Jong SJ   Mok Jee Won JW   Joo Choun-Ki CK   Shin Sangbaie S   Sim Jae-Yoon JY   Myung David D   Bao Zhenan Z   Hahn Sei Kwang SK  

Advanced materials (Deerfield Beach, Fla.) 20220313 18


Smart contact lenses for continuous glucose monitoring (CGM) have great potential for huge clinical impact. To date, their development has been limited by challenges in accurate detection of glucose without hysteresis for tear glucose monitoring to track the blood glucose levels. Here, long-term robust CGM in diabetic rabbits is demonstrated by using bimetallic nanocatalysts immobilized in nanoporous hydrogels in smart contact lenses. After redox reaction of glucose oxidase, the nanocatalysts fa  ...[more]

Similar Datasets

| S-EPMC7182412 | biostudies-literature
| S-EPMC7455488 | biostudies-literature
| S-EPMC7474060 | biostudies-literature
| S-EPMC9534953 | biostudies-literature
| S-EPMC5532712 | biostudies-literature
| S-EPMC6107296 | biostudies-literature
| S-EPMC2783769 | biostudies-literature
| S-EPMC6906081 | biostudies-literature
| S-EPMC9649789 | biostudies-literature
| S-EPMC8948592 | biostudies-literature