Validity of assessing level walking with the 2D motion analysis software TEMPLO and reliability of 3D marker application.


ABSTRACT: In gait analysis, knowledge on validity and reliability of instruments and influences caused by the examiner's performance is of crucial interest. These measurement properties are not yet known for commonly used, low-cost two-dimensional (2D) video-based systems. The purpose of this study was to assess the concurrent validity of a video-based 2D system against a three-dimensional (3D) reference standard, as well as the inter-rater reliability, and test-retest reliability of 3D marker application. Level walking was captured simultaneously by a 2D and a 3D system. Reflective markers were applied independently by three raters and repeated by one rater on a second day. We assessed the agreement between the two systems, as well as reproducibility, and inter-rater agreement of derived spatio-tem