Unknown

Dataset Information

0

Microwave-assisted hydrogen peroxide digestion followed by ICP-OES for determination of metals in selected fuel oils.


ABSTRACT: This work describes a greener and cost-effective microwave-assisted hydrogen peroxide digestion (MA-HPD) with the addition of 1 mL of HNO3 (70% v/v) to enhance extraction of selected metals (Al, Ba, Cd, Co, Cr, Cu, Mg, Na, Ni, Pb, Sb, Ti and V) in crude-oil, diesel, gasoline and kerosene samples prior to inductively coupled plasma-optical emission spectroscopic (ICP-OES) analysis. The most influential parameters of the MA-HPD method were investigated by using multivariate optimization tools (two-level full factorial and central composite designs) and fuel oil certified reference material (NIST1634c). The optimum conditions were observed to be 245 ℃ microwave temperature, 25 min digestion time, 0.1 g sample mass and 5 M H2O2 were the optimum digestion conditions with accepted accuracy (104.8-117.7%) and precision (≤ 4.1%). In overall, the metals that reported high concentrations in the crude oil, diesel, gasoline, and kerosene samples were Na (51.94-58.86 mg/kg) and Mg (36.08-47.4 mg/kg), while Cu was the lowest (0.55-2.89 mg/kg). When comparing the obtained concentration levels with other literature reports, a conclusion can be drawn that South Africa is importing oils of reasonable quality.

SUBMITTER: Mdluli NS 

PROVIDER: S-EPMC10824727 | biostudies-literature | 2024 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Microwave-assisted hydrogen peroxide digestion followed by ICP-OES for determination of metals in selected fuel oils.

Mdluli Njabulo S NS   Knottenbelt Cyril D CD   Nomngongo Philiswa N PN   Mketo Nomvano N  

Scientific reports 20240129 1


This work describes a greener and cost-effective microwave-assisted hydrogen peroxide digestion (MA-HPD) with the addition of 1 mL of HNO<sub>3</sub> (70% v/v) to enhance extraction of selected metals (Al, Ba, Cd, Co, Cr, Cu, Mg, Na, Ni, Pb, Sb, Ti and V) in crude-oil, diesel, gasoline and kerosene samples prior to inductively coupled plasma-optical emission spectroscopic (ICP-OES) analysis. The most influential parameters of the MA-HPD method were investigated by using multivariate optimization  ...[more]

Similar Datasets

| S-EPMC3029800 | biostudies-literature
| S-EPMC9132797 | biostudies-literature
| S-EPMC10987250 | biostudies-literature
| S-EPMC7746717 | biostudies-literature
| S-EPMC11858342 | biostudies-literature
| S-EPMC11656208 | biostudies-literature
| S-EPMC11367618 | biostudies-literature
| S-EPMC4091818 | biostudies-literature
| S-EPMC11643719 | biostudies-literature