Whip-Lock Stitch Is Biomechanically Superior to Whipstitch for Semitendinosus Tendons.


ABSTRACT:

Purpose

To assess the biomechanical performance of different stitching methods using a suturing device by comparing the elongation, stiffness, failure load, and time to stitch completion in cadaveric semitendinosus tendons (STs) and quadriceps tendons (QTs).

Methods

A total of 24 STs and 16 QTs were harvested from cadaveric knee specimens (N = 40). Samples were randomly divided into 2 groups: whipstitch (WS) and whip-lock (WL) stitch. Both tendon ends were clamped to a graft preparation stand, and a 2-part needle was used to place 5 stitches, each 0.5 cm apart. Stitching time was recorded. Samples were preconditioned and then underwent cyclic loading from 50 to 200 N at 1 Hz for 500 cycles, followed by load-to-failure testing at 20 mm/min. Stiffness (in newtons per millimete