Comparison of the Watson formula and bioimpedance spectroscopy for measuring body volume and calculating kt/V in patients with peritoneal dialysis.


ABSTRACT:

Conclusion

There were significant differences between Vwat and Vbis and between Kt/Vwat and Kt/Vbis. Kt/Vwat may underestimate small-solute dialysis adequacy in most cases. Kt/Vbis instead of Kt/Vwat could be accounted for in creating individualized dialysis prescriptions if the patient has no obvious clinical symptoms.

SUBMITTER: Liu S 

PROVIDER: S-EPMC10863529 | biostudies-literature | 2024 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of the Watson formula and bioimpedance spectroscopy for measuring body volume and calculating kt/V in patients with peritoneal dialysis.

Liu Sixiu S   Feng Yuan Y   Zhang Qingyan Q   Lu Jian J   Li Nan N   Liu Ying Y   Jiang Chunming C  

Renal failure 20240212 1


<h4>Conclusion</h4>There were significant differences between Vwat and Vbis and between Kt/Vwat and Kt/Vbis. Kt/Vwat may underestimate small-solute dialysis adequacy in most cases. Kt/Vbis instead of Kt/Vwat could be accounted for in creating individualized dialysis prescriptions if the patient has no obvious clinical symptoms. ...[more]