Unknown

Dataset Information

Three-Dimensional Hinge Axis Orientation Contributes to Simultaneous Alignment Correction in All Three Anatomical Planes in Opening-Wedge High Tibial Osteotomy.


ABSTRACT:

Purpose

To investigate the simultaneous effect of 3-dimensional (3D) hinge axis (HA) orientation on alignment parameters in all 3 anatomical planes in high tibial osteotomy.

Methods

A computed tomography-based 3D model of a human tibia/fibula was used to establish a 3D tibial coordinate system based on the tibial mechanical axis. In here, an HA was positioned and an opening-wedge high tibial osteotomy with a rotation angle of 10° over the HA was simulated. HA rotation in the axial plane ranged from 0° to 90° and HA tilt relative to the axial plane ranged from -20° to +20°. The study quantified the simultaneous effect of HA orientation on change of alignment parameters in all anatomical reference planes.

Results

HA rotation within the tibial axial plane between orienta

SUBMITTER: Veerman QWT 

PROVIDER: S-EPMC10864846 | biostudies-literature | 2024 Apr

REPOSITORIES: biostudies-literature