Quantitative real-time PCR analysis of four genetically modified soybean events using plasmid and genomic DNA calibrators.


ABSTRACT: A calibration curve is required for reliable and accurate quantitative real-time PCR analysis of genetically modified (GM) organisms, necessitating the use of reference materials as calibrators. In this study, two types of DNA calibrators-plasmid DNA (pDNA) and genomic DNA (gDNA)-were used to quantify four GM soybean events (SYHT0H2, MON87751, DAS-44406-6, and DAS-81419-2). The PCR efficiency and linearity for the calibrators adhered to the CODEX guidelines. The conversion factor (Cf) was calculated as the ratio of copies of GM events to those of endogenous genes using the pDNA calibration curve. To assess the accuracy and repeatability of these assays, quantification at GM levels of 3% and 1% was performed. Based on our results, we believe that the pDNA calibrator assessed in this study can be used as a reference material for GMO quantitative analysis and can replace gDNA, especially considering the ease of management and advantages of mass production.

Supplementary information

The online version contains supplementary material available at 10.1007/s10068-023-01392-0.

SUBMITTER: Shin MK 

PROVIDER: S-EPMC10866821 | biostudies-literature | 2024 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative real-time PCR analysis of four genetically modified soybean events using plasmid and genomic DNA calibrators.

Shin Min Ki MK   Jeon Seon Min SM   Park Jong Seok JS  

Food science and biotechnology 20230811 4


A calibration curve is required for reliable and accurate quantitative real-time PCR analysis of genetically modified (GM) organisms, necessitating the use of reference materials as calibrators. In this study, two types of DNA calibrators-plasmid DNA (pDNA) and genomic DNA (gDNA)-were used to quantify four GM soybean events (SYHT0H2, MON87751, DAS-44406-6, and DAS-81419-2). The PCR efficiency and linearity for the calibrators adhered to the CODEX guidelines. The conversion factor (Cf) was calcul  ...[more]

Similar Datasets

| S-EPMC3020864 | biostudies-literature
| S-EPMC11420048 | biostudies-literature
| S-EPMC4064275 | biostudies-literature
| S-EPMC4136099 | biostudies-literature
| S-EPMC3237602 | biostudies-literature
| S-EPMC3866725 | biostudies-literature
| S-EPMC2311272 | biostudies-literature
| S-EPMC2443375 | biostudies-literature
2008-06-16 | E-GEOD-9374 | biostudies-arrayexpress