Optimisation of virtual monoenergetic reconstructions for the diagnosis of pulmonary embolism using photon-counting detector computed tomography angiography.


ABSTRACT:

Purpose

Computed tomography (CT) pulmonary angiography is considered the gold standard for pulmonary embolism (PE) diagnosis, relying on the discrimination between contrast and embolus. Photon-counting detector CT (PCD-CT) generates monoenergetic reconstructions through energy-resolved detection. Virtual monoenergetic images (VMI) at low keV can be used to improve pulmonary artery opacification. While studies have assessed VMI for PE diagnosis on dual-energy CT (DECT), there is a lack of literature on optimal settings for PCD-CT-PE reconstructions, warranting further investigation.

Material and methods

Twenty-five sequential patients who underwent PCD-CT pulmonary angiography for suspicion of acute PE were retrospectively included in this study. Quantitative metrics including signal-to-noise ratio (SNR) and contrast-to-noise (CNR) ratio were calculated for 4 VMI values (40, 60, 80, and 100 keV). Qualitative measures of diagnostic quality were obtained for proximal to distal pulmonary artery branches by 2 cardiothoracic radiologists using a 5-point modified Likert scale.

Results

SNR and CNR were highest for the 40 keV VMI (49.3 ± 22.2 and 48.2 ± 22.1, respectively) and were inversely related to monoenergetic keV. Qualitatively, 40 and 60 keV both exhibited excellent diagnostic quality (mean main pulmonary artery: 5.0 ± 0 and 5.0 ± 0; subsegmental pulmonary arteries 4.9 ± 0.1 and 4.9 ± 0.1, respectively) while distal segments at high (80-100) keVs had worse quality.

Conclusions

40 keV was the best individual VMI for the detection of pulmonary embolism by quantitative metrics. Qualitatively, 40-60 keV reconstructions may be used without a significant decrease in subjective quality. VMIs at higher keV lead to reduced opacification of the distal pulmonary arteries, resulting in decreased image quality.

SUBMITTER: Chamberlin JH 

PROVIDER: S-EPMC10867981 | biostudies-literature | 2024

REPOSITORIES: biostudies-literature

altmetric image

Publications

Optimisation of virtual monoenergetic reconstructions for the diagnosis of pulmonary embolism using photon-counting detector computed tomography angiography.

Chamberlin Jordan H JH   Toth Adrienn A   Hinen Shaun S   O'Doherty Jim J   Baruah Dhiraj D   Maisuria Dhruw D   McGuire Aaron A   Knight Heather H   Schoepf U Joseph UJ   Munden Reginald F RF   Kabakus Ismail M IM  

Polish journal of radiology 20240131


<h4>Purpose</h4>Computed tomography (CT) pulmonary angiography is considered the gold standard for pulmonary embolism (PE) diagnosis, relying on the discrimination between contrast and embolus. Photon-counting detector CT (PCD-CT) generates monoenergetic reconstructions through energy-resolved detection. Virtual monoenergetic images (VMI) at low keV can be used to improve pulmonary artery opacification. While studies have assessed VMI for PE diagnosis on dual-energy CT (DECT), there is a lack of  ...[more]

Similar Datasets

| S-EPMC9222087 | biostudies-literature
| S-EPMC10597903 | biostudies-literature
| S-EPMC11294310 | biostudies-literature
| S-EPMC11631184 | biostudies-literature
| S-EPMC10667372 | biostudies-literature
| S-EPMC9665022 | biostudies-literature
| S-EPMC10766624 | biostudies-literature
| S-EPMC10968735 | biostudies-literature
| S-EPMC11386360 | biostudies-literature
| S-EPMC11592515 | biostudies-literature