Unknown

Dataset Information

0

Stable fixation of an ultra-short femoral neck-preserving hip prosthesis: a 5-year RSA, DXA, and clinical prospective outcome study of 48 patients.


ABSTRACT:

Background and purpose

We previously showed promising primary stability and preservation of bone stock with the ultra-short neck-loading hip implant in total hip arthroplasty (THA). The aim of this study was to evaluate clinical outcome, implant stability, and bone mineral density (BMD).

Methods

50 patients were treated with the ultra-short neck Primoris hip implant at baseline and 48 were available for evaluation at 5-year follow-up. 5 different patient-reported outcome measures (PROMs) including hip-specific scores, disease-specific and generic quality of life outcome measures, and an activity score were used. Furthermore, implant stability using radiostereometric analysis (RSA) and assessment of periprosthetic BMD using dual-energy X-ray absorptiometry (DXA) were applied.

Results

By 1-year follow-up, all PROMs showed improvements and remained high at 5-year follow-up. After initial distal translation (subsidence) and negative rotation around the z-axis (varus tilt) the implant showed stable fixation at 5-year follow-up with no further migration beyond 12 months. In the regions of interest (ROI) 3 and 4, BMD remained stable. In ROI 2, further bone loss of 12% was found at 5-year follow-up.

Conclusion

Clinical outcome including PROMs was satisfying throughout the 5-year follow-up period. The hip implant remains stable with both bone preservation and loss 5 years after surgery.

SUBMITTER: Christiansen JD 

PROVIDER: S-EPMC10886218 | biostudies-literature | 2024 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Stable fixation of an ultra-short femoral neck-preserving hip prosthesis: a 5-year RSA, DXA, and clinical prospective outcome study of 48 patients.

Christiansen Janus D JD   Laursen Mogens M   Blunn Gordon W GW   Nielsen Poul T PT  

Acta orthopaedica 20240223


<h4>Background and purpose</h4>We previously showed promising primary stability and preservation of bone stock with the ultra-short neck-loading hip implant in total hip arthroplasty (THA). The aim of this study was to evaluate clinical outcome, implant stability, and bone mineral density (BMD).<h4>Methods</h4>50 patients were treated with the ultra-short neck Primoris hip implant at baseline and 48 were available for evaluation at 5-year follow-up. 5 different patient-reported outcome measures  ...[more]

Similar Datasets

| S-EPMC10127061 | biostudies-literature
| S-EPMC10043403 | biostudies-literature
| S-EPMC5655934 | biostudies-literature
| S-EPMC9483172 | biostudies-literature
| S-EPMC9192444 | biostudies-literature
| S-EPMC5892388 | biostudies-literature
| S-EPMC11246254 | biostudies-literature
| S-EPMC4940590 | biostudies-literature
| S-EPMC7364523 | biostudies-literature
| S-EPMC3986622 | biostudies-literature