Unknown

Dataset Information

Technical and Clinical Outcome of Low-Milliampere CT Fluoroscopy-Guided Percutaneous Drainage Placement in Abdominal Fluid Collections after Liver Transplantation: A 16-Year Retrospective Analysis of 50 Consecutive Patients.


ABSTRACT:

Purpose

Evaluation of the effectiveness of CT-guided drainage (CTD) placement in managing symptomatic postoperative fluid collections in liver transplant patients. The assessment included technical success, clinical outcomes, and the occurrence of complications during the peri-interventional period.

Methods

Analysis spanned the years 2005 to 2020 and involved 91 drain placement sessions in 50 patients using percutaneous transabdominal or transhepatic access. Criteria for technical success (TS) included (a) achieving adequate drainage of the fluid collection and (b) the absence of peri-interventional complications necessitating minor or prolonged hospitalization. Clinical success (CS) was characterized by (a) a reduction or normalization of inflammatory blood parameters withi

SUBMITTER: Stahl R 

PROVIDER: S-EPMC10887879 | biostudies-literature | 2024 Feb

REPOSITORIES: biostudies-literature