ABSTRACT: Background
Pulsed-field ablation (PFA) has shown favourable data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI). We sought to compare procedural and 1-year follow-up data of patients with paroxysmal atrial fibrillation (AF) undergoing PVI using PFA, cryoballoon ablation (CBA) and radiofrequency ablation (RFA).Methods
Consecutive patients with paroxysmal AF undergoing a first PVI with PFA at our institution were included. For comparison, patients with paroxysmal AF undergoing a first PVI with CBA and RFA were selected using a 1:2:2 propensity score matching. The PFA group followed the standard 32-applications lesion-set protocol, the CBA group a time-to-effect plus 2-min strategy, and the RFA group the CLOSE protocol. Patients were followed with 7d-Holter ECGs 3, 6, and 12 months after ablation. The primary endpoint was recurrence of atrial tachyarrhythmia (ATa) following a blanking period of 3 months.Results
A total of 200 patients were included (PFA n = 40; CBA n = 80; RFA n = 80). Median procedure times were shortest with CBA (75 min) followed by PFA (94 min) and RFA (182 min; p < 0.001). Fluoroscopy dose was lowest with RFA (1.6Gycm2) followed by PFA (5.0Gycm2) and CBA (5.7Gycm2; p < 0.001). After a 1-year follow-up, freedom from ATa recurrence was 85.0% with PFA, 66.2% with CBA and 73.8% with RFA (p = 0.12 PFA vs. CBA; p = 0.27 PFA vs. RFA).Conclusion
In a propensity score matched analysis of patients with paroxysmal AF, freedom from any ATa 1 year after PVI using PFA was favourable and at least as good as for PVI with CBA or RFA.
SUBMITTER: Maurhofer J
PROVIDER: S-EPMC10902096 | biostudies-literature | 2024 Mar
REPOSITORIES: biostudies-literature
Maurhofer Jens J Kueffer Thomas T Madaffari Antonio A Stettler Robin R Stefanova Anita A Seiler Jens J Thalmann Gregor G Kozhuharov Nikola N Galuszka Oskar O Servatius Helge H Haeberlin Andreas A Noti Fabian F Tanner Hildegard H Roten Laurent L Reichlin Tobias T
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing 20230930 2
<h4>Background</h4>Pulsed-field ablation (PFA) has shown favourable data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI). We sought to compare procedural and 1-year follow-up data of patients with paroxysmal atrial fibrillation (AF) undergoing PVI using PFA, cryoballoon ablation (CBA) and radiofrequency ablation (RFA).<h4>Methods</h4>Consecutive patients with paroxysmal AF undergoing a first PVI with PFA at our institution were included. For comparison, patients w ...[more]