Assessment and indicators of kinematic behavior and perceived fatigability.


ABSTRACT:

Objective

The objective of this study was to investigate the relationship between upper limb kinetics and perceived fatigability in elderly individuals during an upper limb position sustained isometric task.

Methods

A total of 31 elderly participants, 16 men (72.94±4.49 years) and 15 women (72.27±6.05 years), performed a upper limb position sustained isometric task. Upper-limb acceleration was measured using an inertial measurement unit. Perceived fatigability was measured using the Borg CR10 scale.

Results

Higher mean acceleration in the x-axis throughout the activity was associated with higher final perceived fatigability scores. Moderate correlations were observed between perceived fatigability variation and mean acceleration cutoffs in all axes during the second half of the activity. In women, significant correlations were found between all perceived fatigability cutoffs and mean acceleration in the y- and x-axes. However, in men, the relationships between perceived fatigability variation and mean acceleration were more extensive and stronger.

Conclusion

The acceleration pattern of the upper limb is linked to perceived fatigability scores and variation, with differences between sexes. Monitoring upper limb acceleration using a single inertial measurement unit can be a useful and straightforward method for identifying individuals who may be at risk of experiencing high perceived fatigability or task failure.

SUBMITTER: Silva-Migueis H 

PROVIDER: S-EPMC10903270 | biostudies-literature | 2024

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Objective</h4>The objective of this study was to investigate the relationship between upper limb kinetics and perceived fatigability in elderly individuals during an upper limb position sustained isometric task.<h4>Methods</h4>A total of 31 elderly participants, 16 men (72.94±4.49 years) and 15 women (72.27±6.05 years), performed a upper limb position sustained isometric task. Upper-limb acceleration was measured using an inertial measurement unit. Perceived fatigability was measured using t  ...[more]

Similar Datasets

| S-EPMC8127403 | biostudies-literature
| S-EPMC10215633 | biostudies-literature
| S-EPMC9130341 | biostudies-literature
| S-EPMC9421030 | biostudies-literature
| S-EPMC11467958 | biostudies-literature
| S-EPMC7395299 | biostudies-literature
| S-EPMC8974332 | biostudies-literature
| S-EPMC6759892 | biostudies-literature
| S-EPMC7494027 | biostudies-literature
| S-EPMC8355455 | biostudies-literature