Early outcomes of transapical mitral valve implantation versus surgical replacement in matched elderly patients at intermediate surgical risk.


ABSTRACT:

Background

Data comparing transcatheter mitral valve implantation (TMVI) with surgical mitral valve replacement (SMVR) are lacking.

Aims

This study sought to compare the 30-day Valve Academic Research Consortium (VARC)-3 device success of TMVI with that of SMVR.

Methods

Matching protocol combined exact matching (sex, atrial fibrillation, previous surgical aortic valve replacement [SAVR] or coronary artery bypass grafting [CABG]), coarsened exact matching (age) and propensity score matching (body mass index, mitral valve pathology and concomitant tricuspid regurgitation).

Results

A total of 40 Tendyne TMVI and 80 SMVR patients with similar baseline characteristics were analysed (TMVI vs SMVR): age (78 years [interquartile range [{IQR} 75; 80] vs 78 years [IQR 73

SUBMITTER: Ziegelmueller JA 

PROVIDER: S-EPMC10905192 | biostudies-literature | 2024 Mar