Differences in serum and plasma levels of microRNAs and their time-course changes after blood collection.


ABSTRACT:

Background

Serum and plasma are used for measurements of microRNAs (miRNAs) as biomarkers of various diseases. However, no consistent findings have been obtained regarding differences in serum and plasma levels of miRNAs. The purpose of this study was to clarify differences in serum and plasma levels of total miRNAs and their time-course changes after blood collection.

Methods

Venous blood was collected from healthy men, and samples were prepared at the time points of 0, 15, 30, 60 and 180 min after blood collection for plasma and after clot formation for serum. Levels of total miRNAs were analyzed by the hybridization method using the 3D-Gene miRNA Oligo chip.

Results

About one third of 2632 miRNAs tested showed levels high enough for comparison of serum and plasma l

SUBMITTER: Wakabayashi I 

PROVIDER: S-EPMC10924119 | biostudies-literature | 2024 Mar