Unknown

Dataset Information

0

Cost-utility of real-time continuous glucose monitoring versus self-monitoring of blood glucose in people with insulin-treated Type II diabetes in France.


ABSTRACT: Aim: Clinical trials and real-world data for Type II diabetes both show that glycated hemoglobin (HbA1c) levels and hypoglycemia occurrence can be reduced by real-time continuous glucose monitoring (rt-CGM) versus self-monitoring of blood glucose (SMBG). The present cost-utility study investigated the long-term health economic outcomes associated with using rt-CGM versus SMBG in people with insulin-treated Type II diabetes in France. Materials & methods: Effectiveness data were obtained from a real-world study, which showed rt-CGM reduced HbA1c by 0.56% (6.1 mmol/mol) versus sustained SMBG. Analyses were conducted using the IQVIA Core Diabetes Model. A French payer perspective was adopted over a lifetime horizon for a cohort aged 64.5 years with baseline HbA1c of 8.3% (67 mmol/mol). A willingness-to-pay threshold of €147,093 was used, and future costs and outcomes were discounted at 4% annually. Results: The analysis projected quality-adjusted life expectancy was 8.50 quality-adjusted life years (QALYs) for rt-CGM versus 8.03 QALYs for SMBG (difference: 0.47 QALYs), while total mean lifetime costs were €93,978 for rt-CGM versus €82,834 for SMBG (difference: €11,144). This yielded an incremental cost-utility ratio (ICUR) of €23,772 per QALY gained for rt-CGM versus SMBG. Results were particularly sensitive to changes in the treatment effect (i.e., change in HbA1c), annual price and quality of life benefit associated with rt-CGM, SMBG frequency, baseline patient age and complication costs. Conclusion: The use of rt-CGM is likely to be cost-effective versus SMBG for people with insulin-treated Type II diabetes in France.

SUBMITTER: Alshannaq H 

PROVIDER: S-EPMC10945438 | biostudies-literature | 2024 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Cost-utility of real-time continuous glucose monitoring versus self-monitoring of blood glucose in people with insulin-treated Type II diabetes in France.

Alshannaq Hamza H   Pollock Richard F RF   Joubert Michael M   Ahmed Waqas W   Norman Gregory J GJ   Lynch Peter M PM   Roze Stéphane S  

Journal of comparative effectiveness research 20240131 3


<b>Aim:</b> Clinical trials and real-world data for Type II diabetes both show that glycated hemoglobin (HbA1c) levels and hypoglycemia occurrence can be reduced by real-time continuous glucose monitoring (rt-CGM) versus self-monitoring of blood glucose (SMBG). The present cost-utility study investigated the long-term health economic outcomes associated with using rt-CGM versus SMBG in people with insulin-treated Type II diabetes in France. <b>Materials & methods:</b> Effectiveness data were obt  ...[more]

Similar Datasets

| S-EPMC3180394 | biostudies-literature
| S-EPMC10666454 | biostudies-literature