Utilizing Longitudinal Chest X-Rays and Reports to Pre-fill Radiology Reports.


ABSTRACT: Despite the reduction in turn-around times in radiology reporting with the use of speech recognition software, persistent communication errors can significantly impact the interpretation of radiology reports. Pre-filling a radiology report holds promise in mitigating reporting errors, and despite multiple efforts in literature to generate comprehensive medical reports, there lacks approaches that exploit the longitudinal nature of patient visit records in the MIMIC-CXR dataset. To address this gap, we propose to use longitudinal multi-modal data, i.e., previous patient visit CXR, current visit CXR, and the previous visit report, to pre-fill the "findings" section of the patient's current visit. We first gathered the longitudinal visit information for 26,625 patients from the MIMIC-CXR dataset, and created a new dataset called Longitudinal-MIMIC. With this new dataset, a transformer-based model was trained to capture the multi-modal longitudinal information from patient visit records (CXR images + reports) via a cross-attention-based multi-modal fusion module and a hierarchical memory-driven decoder. In contrast to previous works that only uses current visit data as input to train a model, our work exploits the longitudinal information available to pre-fill the "findings" section of radiology reports. Experiments show that our approach outperforms several recent approaches by ≥3% on F1 score, and ≥2% for BLEU-4, METEOR and ROUGE-L respectively. Code will be published at https://github.com/CelestialShine/Longitudinal-Chest-X-Ray.

SUBMITTER: Zhu Q 

PROVIDER: S-EPMC10947431 | biostudies-literature | 2023 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Utilizing Longitudinal Chest X-Rays and Reports to Pre-fill Radiology Reports.

Zhu Qingqing Q   Mathai Tejas Sudharshan TS   Mukherjee Pritam P   Peng Yifan Y   Summers Ronald M RM   Lu Zhiyong Z  

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention 20231001


Despite the reduction in turn-around times in radiology reporting with the use of speech recognition software, persistent communication errors can significantly impact the interpretation of radiology reports. Pre-filling a radiology report holds promise in mitigating reporting errors, and despite multiple efforts in literature to generate comprehensive medical reports, there lacks approaches that exploit the longitudinal nature of patient visit records in the MIMIC-CXR dataset. To address this g  ...[more]

Similar Datasets

| S-EPMC7901713 | biostudies-literature
| S-EPMC10382552 | biostudies-literature
| S-EPMC9621405 | biostudies-literature
| S-EPMC9206650 | biostudies-literature
| S-EPMC6841833 | biostudies-literature
| S-EPMC7807990 | biostudies-literature
| S-EPMC11574816 | biostudies-literature
| S-EPMC10811038 | biostudies-literature
| S-EPMC10122604 | biostudies-literature
| S-EPMC2754327 | biostudies-literature