Unknown

Dataset Information

0

A systematic algorithm for large-bore arterial access closure after TAVI: the TAVI-MultiCLOSE study.


ABSTRACT:

Background

Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality.

Aims

The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI.

Methods

All consecutive TF-TAVI cases in which the MultiCLOSE vascular closure algorithm was used were prospectively included in a multicentre, observational study. This stepwise algorithm entails the reinsertion of a 6-8 Fr sheath (primary access) following the initial preclosure with one or two suture-based vascular closure devices (VCDs). This provides the operator with the opportunity to perform a quick and easy angiographic control and tailor the final vascular closure with either an additional suture- or plug-based VCD, or neither of these.

Results

Among 630 patients who underwent TF-TAVI utilising the MultiCLOSE algorithm, complete arterial haemostasis was achieved in 616 patients (98%). VCD failure occurred in 14 patients (2%), treated with either balloon inflation (N=1), covered stent (N=12) or surgical repair (N=1). Overall, this vascular closure approach resulted in a minor and major vascular complication rate of 2.2% and 0.6%, respectively. At 30 days, only one new minor vascular complication (0.2%) was noted. In-hospital and 30-day all-cause mortality rates were 0.2% and 1.0%, respectively.

Conclusions

Use of the MultiCLOSE vascular closure algorithm was demonstrated to contribute to an easy, safe, efficacious and durable vascular closure after TF-TAVI, resulting in a major vascular complication rate of less than 1%.

SUBMITTER: Rosseel L 

PROVIDER: S-EPMC10949328 | biostudies-literature | 2024 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

A systematic algorithm for large-bore arterial access closure after TAVI: the TAVI-MultiCLOSE study.

Rosseel Liesbeth L   Montarello Nicholas J NJ   Nuyens Philippe P   Tirado-Conte Gabriella G   Quagliana Angelo A   Cornelis Kristoff K   Floré Vincent V   Rosseel Michael M   Bieliauskas Gintautas G   Sondergaard Lars L   De Backer Ole O  

EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology 20240318 6


<h4>Background</h4>Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality.<h4>Aims</h4>The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI.<h4>Methods</h4>All consecutive TF-TAVI cases in which the Mu  ...[more]

Similar Datasets

| S-EPMC9238521 | biostudies-literature
| S-EPMC8246962 | biostudies-literature
| S-EPMC9243605 | biostudies-literature
| S-EPMC7078947 | biostudies-literature
| S-EPMC5314616 | biostudies-literature