Unknown

Dataset Information

Pulsed field versus cryoballoon ablation for atrial fibrillation: a real-world observational study on procedural outcomes and efficacy.


ABSTRACT:

Introduction

Atrial fibrillation often necessitates catheter ablation when antiarrhythmic drug therapy fails. Single-shot technologies using thermal energy, such as cryoballoon ablation, are commonly used, but pulsed field ablation (PFA), an innovative non-thermal ablation technique, is a potential alternative. This retrospective observational study aimed to compare the safety and efficacy of cryoballoon ablation and PFA in patients undergoing their first pulmonary vein isolation (PVI) procedure for atrial fibrillation treatment.

Methods

We utilised real-world data from patients who underwent PVI using cryoballoon ablation or PFA. The primary outcome encompassed procedural complications, including phrenic nerve palsy, cardiac tamponade, thromboembolic complications, bleeding

SUBMITTER: van de Kar MRD 

PROVIDER: S-EPMC10951164 | biostudies-literature | 2024 Apr