Transcatheter aortic valve implantation for structural valve deterioration of homograft surgical aortic valve using SAPIEN3 Ultra RESILIA: a case report.


ABSTRACT:

Background

There are a few case reports regarding transcatheter aortic valve implantation (TAVI) for deteriorated surgical homograft.

Case summary

We present a case of severe structural valve deterioration (SVD) of homograft surgical aortic valve presenting severe aortic regurgitation in an 84-year-old man with decompensated heart failure. We performed TAVI in homograft valve using 23 mm SAPIEN3 Ultra RESILIA. The resulting grade of paravalvular regurgitation was trace, the post-operative effective orifice area (EOA) was 1.66 cm2 (index EOA: 1.19 cm2/m2), and device success was achieved.

Discussion

Stented bioprosthetic valves are more commonly implanted than mechanical and stentless bioprosthetic valves. In the 1980s and the early 199