Validity and Reliability of a Smartphone Application for Home Measurement of Four-Meter Gait Speed in Older Adults.


ABSTRACT: The four-meter gait speed (4MGS) is a recommended physical performance test in older adults but is challenging to implement clinically. We developed a smartphone application (App) with a four-meter ribbon for remote 4MGS testing at home. This study aimed to assess the validity and reliability of this smartphone App-based assessment of the home 4MGS. We assessed the validity of the smartphone App by comparing it against a gold standard video assessment of the 4MGS conducted by study staff visiting community-dwelling older adults and against the stopwatch-based measurement. Moreover, we assessed the test-retest reliability in two supervised sessions and three additional sessions performed by the participants independently, without staff supervision. The 4MGS measured by the smartphone App was highly correlated with video-based 4MGS (r = 0.94), with minimal differences (mean = 0.07 m/s, ± 1.96 SD = 0.12) across a range of gait speeds. The test-retest reliability for the smartphone App 4MGS was high (ICC values: 0.75 to 0.93). The home 4MGS in older adults can be measured accurately and reliably using a smartphone in the pants pocket and a four-meter strip of ribbon. Leveraging existing technology carried by a significant portion of the older adult population could overcome barriers in busy clinical settings for this well-established objective mobility test.

SUBMITTER: Lee PA 

PROVIDER: S-EPMC10968134 | biostudies-literature | 2024 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Validity and Reliability of a Smartphone Application for Home Measurement of Four-Meter Gait Speed in Older Adults.

Lee Pei-An PA   DuMontier Clark C   Yu Wanting W   Ask Levi L   Zhou Junhong J   Testa Marcia A MA   Kim Dae D   Abel Gregory G   Travison Tom T   Manor Brad B   Lo On-Yee OY  

Bioengineering (Basel, Switzerland) 20240306 3


The four-meter gait speed (4MGS) is a recommended physical performance test in older adults but is challenging to implement clinically. We developed a smartphone application (App) with a four-meter ribbon for remote 4MGS testing at home. This study aimed to assess the validity and reliability of this smartphone App-based assessment of the home 4MGS. We assessed the validity of the smartphone App by comparing it against a gold standard video assessment of the 4MGS conducted by study staff visitin  ...[more]

Similar Datasets

| S-EPMC11527157 | biostudies-literature
| S-EPMC6716662 | biostudies-literature
| S-EPMC10197211 | biostudies-literature