Standardization of a CT Protocol for Imaging Patients with Suspected COVID-19-A RACOON Project.


ABSTRACT: CT protocols that diagnose COVID-19 vary in regard to the associated radiation exposure and the desired image quality (IQ). This study aims to evaluate CT protocols of hospitals participating in the RACOON (Radiological Cooperative Network) project, consolidating CT protocols to provide recommendations and strategies for future pandemics. In this retrospective study, CT acquisitions of COVID-19 patients scanned between March 2020 and October 2020 (RACOON phase 1) were included, and all non-contrast protocols were evaluated. For this purpose, CT protocol parameters, IQ ratings, radiation exposure (CTDIvol), and central patient diameters were sampled. Eventually, the data from 14 sites and 534 CT acquisitions were analyzed. IQ was rated good for 81% of the evaluated examinations. Motion, beam-hardening artefacts, or image noise were reasons for a suboptimal IQ. The tube potential ranged between 80 and 140 kVp, with the majority between 100 and 120 kVp. CTDIvol was 3.7 ± 3.4 mGy. Most healthcare facilities included did not have a specific non-contrast CT protocol. Furthermore, CT protocols for chest imaging varied in their settings and radiation exposure. In future, it will be necessary to make recommendations regarding the required IQ and protocol parameters for the majority of CT scanners to enable comparable IQ as well as radiation exposure for different sites but identical diagnostic questions.

SUBMITTER: Steuwe A 

PROVIDER: S-EPMC10968361 | biostudies-literature | 2024 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Standardization of a CT Protocol for Imaging Patients with Suspected COVID-19-A RACOON Project.

Steuwe Andrea A   Kamp Benedikt B   Afat Saif S   Akinina Alena A   Aludin Schekeb S   Bas Elif Gülsah EG   Berger Josephine J   Bohrer Evelyn E   Brose Alexander A   Büttner Susanne Martina SM   Ehrengut Constantin C   Gerwing Mirjam M   Grosu Sergio S   Gussew Alexander A   Güttler Felix F   Heinrich Andreas A   Jiraskova Petra P   Kloth Christopher C   Kottlors Jonathan J   Kuennemann Marc-David MD   Liska Christian C   Lubina Nora N   Manzke Mathias M   Meinel Felix G FG   Meyer Hans-Jonas HJ   Mittermeier Andreas A   Persigehl Thorsten T   Schmill Lars-Patrick LP   Steinhardt Manuel M   The Racoon Study Group   Antoch Gerald G   Valentin Birte B  

Bioengineering (Basel, Switzerland) 20240222 3


CT protocols that diagnose COVID-19 vary in regard to the associated radiation exposure and the desired image quality (IQ). This study aims to evaluate CT protocols of hospitals participating in the RACOON (Radiological Cooperative Network) project, consolidating CT protocols to provide recommendations and strategies for future pandemics. In this retrospective study, CT acquisitions of COVID-19 patients scanned between March 2020 and October 2020 (RACOON phase 1) were included, and all non-contr  ...[more]

Similar Datasets

| S-EPMC8758079 | biostudies-literature
| S-EPMC8374412 | biostudies-literature
| S-EPMC8267782 | biostudies-literature
| S-EPMC7537264 | biostudies-literature
| S-EPMC7185104 | biostudies-literature
| S-EPMC10352333 | biostudies-literature
| S-EPMC8210511 | biostudies-literature
| S-BSST416 | biostudies-other
| S-EPMC7358325 | biostudies-literature
| S-EPMC7467843 | biostudies-literature