Relaxation Along a Fictitious Field, continuous wave T1rho, adiabatic T1rho and adiabatic T2rho imaging of human gliomas at 3T: A feasibility study.
Ontology highlight
ABSTRACT: In pre-clinical models of brain gliomas, Relaxation Along a Fictitious Field in second rotating frame (TRAFF2), continues wave T1rho (T1ρcw), adiabatic T1rho (T1ρadiab), and adiabatic T2rho (T2ρadiab) relaxation time mappings have demonstrated potential to non-invasively characterize brain gliomas. Our aim was to evaluate the feasibility and potential of 4 different spin lock methods at 3T to characterize primary brain glioma. 22 patients (26-72 years) with suspected primary glioma. T1ρcw was performed using pulse peak amplitude of 500Hz and pulse train durations of 40 and 80 ms while the corresponding values for T1ρadiab, T2ρadiab, TRAFF2 were 500/500/500Hz and 48 and 96, 64 and 112, 45 and 90 ms, respectively. The parametric maps were calculated using a monoexponential model. Molecular p
SUBMITTER: Jambor I
PROVIDER: S-EPMC10984536 | biostudies-literature | 2024
REPOSITORIES: biostudies-literature
ACCESS DATA