Unknown

Dataset Information

Ultrasensitive ImmunoMag-CRISPR Lateral Flow Assay for Point-of-Care Testing of Urinary Biomarkers.


ABSTRACT: Rapid, accurate, and noninvasive detection of biomarkers in saliva, urine, or nasal fluid is essential for the identification, early diagnosis, and monitoring of cancer, organ failure, transplant rejection, vascular diseases, autoimmune disorders, and infectious diseases. We report the development of an Immuno-CRISPR-based lateral flow assay (LFA) using antibody-DNA barcode complexes with magnetic enrichment of the target urinary biomarkers CXCL9 and CXCL10 for naked eye detection (ImmunoMag-CRISPR LFA). An intermediate approach involving a magnetic bead-based Immuno-CRISPR assay (ImmunoMag-CRISPR) resulted in a limit of detection (LOD) of 0.6 pg/mL for CXCL9. This value surpasses the detection limits achieved by previously reported assays. The highly sensitive detection method was then re

SUBMITTER: Lee I 

PROVIDER: S-EPMC11090086 | biostudies-literature | 2024 Jan

REPOSITORIES: biostudies-literature