Assessing hypoxic respiratory failure in mechanically ventilated neonates: A comparative study of oxygen saturation index and oxygenation index.


ABSTRACT:

Objective

To investigate the correlation between oxygen saturation index (OSI) and oxygenation index (OI) for evaluating the blood oxygenation status in neonates with respiratory failure requiring mechanical ventilation support and to assess the predictive capability of OSI in determining clinically relevant OI cutoffs.

Methods

A prospective study was conducted on neonates who received invasive mechanical ventilation at the neonatal intensive care unit of tertiary hospital in Vietnam. Bland-Altman analysis was utilized to evaluate the agreement between OSI and OI.

Results

A total of 123 neonates, including both term and preterm infants, were included in the study. A high agreement rate of 94.3% within the 95% limits of agreement (between OI and OSI), with a narrow sim