Quantification of periaortic adipose tissue in contrast-enhanced CT angiography: technical feasibility and methodological considerations.


ABSTRACT: To examine the feasibility of the quantification of abdominal periaortic fat tissue (PaFT) (tissue within - 45 to - 195 HU) in enhanced CT-angiographies compared to unenhanced CT-scans and identify methodological issues affecting its clinical implementation. Using OsirixMD, PaFT volume and mean HU value were retrospectively measured within a 5 mm periaortic ring in paired unenhanced and enhanced abdominal aortic CT-scans. The correlation between PaFT values was examined in a derivation cohort (n = 101) and linear regression analysis produced correction factors to convert values from enhanced into values from unenhanced CTs. The conversion factors were then applied to enhanced CTs in a different validation cohort (n = 47) and agreement of corrected enhanced values with values from unenhance