Project description:Introduction: Pediatric spinal deformity involves a complex 3-dimensional (3D) deformity that increases the risk of pedicle screw placement due to the close proximity of neurovascular structures. To increase screw accuracy, improve patient safety, and minimize surgical complications, the placement of pedicle screws is evolving from freehand techniques to computer-assisted navigation and to the introduction of robotic-assisted placement. Purpose: The aim of this review was to review the current literature on the use of robotic navigation in pediatric spinal deformity surgery to provide both an error analysis of these techniques and to provide recommendations to ensure its safe application. Methods: A narrative review was conducted in April 2021 using the MEDLINE (PubMed) database. Studies were included if they were peer-reviewed retrospective or prospective studies, included pediatric patients, included a primary diagnosis of pediatric spine deformity, utilized robotic-assisted spinal surgery techniques, and reported thoracic or lumbar pedicle screw breach rates or pedicle screw malpositioning. Results: In the few studies published on the use of robotic techniques in pediatric spinal deformity surgery, several found associations between the technology and increased rates of screw placement accuracy, reduced rates of breach, and minimal complications. All were retrospective studies. Conclusions: Current literature is of a low level of evidence; nonetheless, the findings suggest the accuracy and safety of robotic-assisted spinal surgery in pediatric pedicle screw placement. The introduction of robotics may drive further advances in less invasive pediatric spinal deformity surgery. Further study is warranted.
Project description:BackgroundThe incidence of cancer patients with bone metastasis is increasing annually. With the advancement of medical treatment for malignant tumors, the survival time of patients with spinal metastases is gradually being prolonged, and adjacent segment vertebral metastases often occur after conventional pedicle screw (CPS) surgery, leading to spinal instability, pain and nerve function injury again, with repeated symptoms. Combined pedicle screw fixation can maintain or reconstruct the spinal stability. This study aimed to investigate the efficacy and safety of cement-augmented fenestrated pedicle screws in the posterior approach for spinal metastases by comparing with CPS.MethodsFrom January 2017 to August 2019, 52 patients with spinal metastases who underwent separation surgery and internal fixation via posterior approach were retrospectively enrolled. Cases were divided into the cement-augmented pedicle screw (CAPS) group (28 cases) and the CPS group (24 cases). The baseline data [age, gender, surgical sites, surgical segment, Tomita classification, Tomita score, Tokuhashi score, spinal instability neoplastic score (SINS)], surgical information, and local progression-free survival (PFS) time were compared between the two groups. Every patient was followed-up every 3 months with imaging examination. The visual analog scale (VAS) score and Frankel grade of the two groups were recorded before and 3 months after the operation were used to evaluate the efficacy. The operation time, the amount of intraoperative blood loss, the amount of bone cement injected in the pedicle screw group, and the complications of the surgery were recorded to evaluate the safety of CAPS.ResultsThe baseline characteristics were comparable between the two group. Compared with the CPS group, the CAPS group showed significantly longer operation time (163±20 vs. 138±18 min, P<0.001) and lower VAS scores (2.93±1.33 vs. 4.17±1.34, P=0.002). Adjacent segment vertebral metastasis occurred in 10 cases (2 in the CAPS group and 8 in the CPS group, P=0.017). Internal implant failure occurred in 8 cases (1 in the CAPS group and 7 in the CPS group, P=0.011). Compared with the CPS group, the CAPS group had a significantly longer local PFS time (P<0.05).ConclusionsCAPS could be a safe and effective choice in surgery for spinal metastases with the posterior approach.
Project description:BackgroundIn spinal revision surgery, previous pedicle screws (PS) may need to be replaced with new implants. Failure to accurately identify the brand of PS-based instrumentation preoperatively may increase the risk of perioperative complications. This study aimed to develop and validate an optimal deep learning (DL) model to identify the brand of PS-based instrumentation on plain radiographs of spine (PRS) using anteroposterior (AP) and lateral images.MethodsA total of 529 patients who received PS-based instrumentation from seven manufacturers were enrolled in this retrospective study. The postoperative PRS were gathered as ground truths. The training, validation, and testing datasets contained 338, 85, and 106 patients, respectively. YOLOv5 was used to crop out the screws' trajectory, and the EfficientNet-b0 model was used to develop single models (AP, Lateral, Merge, and Concatenated) based on the different PRS images. The ensemble models were different combinations of the single models. Primary outcomes were the models' performance in accuracy, sensitivity, precision, F1-score, kappa value, and area under the curve (AUC). Secondary outcomes were the relative performance of models versus human readers and external validation of the DL models.ResultsThe Lateral model had the most stable performance among single models. The discriminative performance was improved by the ensemble method. The AP + Lateral ensemble model had the most stable performance, with an accuracy of 0.9434, F1 score of 0.9388, and AUC of 0.9834. The performance of the ensemble models was comparable to that of experienced orthopedic surgeons and superior to that of inexperienced orthopedic surgeons. External validation revealed that the Lat + Concat ensemble model had the best accuracy (0.9412).ConclusionThe DL models demonstrated stable performance in identifying the brand of PS-based instrumentation based on AP and/or lateral images of PRS, which may assist orthopedic spine surgeons in preoperative revision planning in clinical practice.
Project description:BackgroundModular pedicle screws have a separate head that can be intraoperatively assembled to the inserted shank. The aim of this study was to report associated intra- and post-operative complications and reoperation rates of posterior spinal fixations with modular pedicle screws at a single center.MethodsA retrospective, institutional chart review was performed on 285 patients who underwent posterior thoracolumbar spinal fusion with modular pedicle screw fixation between January 1, 2017, and December 31, 2019. The primary outcome was failure of the modular screw component. Other measures recorded were length of follow-up, other complications, and need for additional procedures.ResultsThere were 1,872 modular pedicle screws (average 6.6 per case). There were no (0.0%) screw head dissociations at the rod screw junction. There was 20.8% overall complication rate (59/285) with 25 reoperations: 6 due to non-union and rod breakage, 5 for screw loosening, 7 for adjacent segment disease, 1 for acute postoperative radiculopathy, 1 for epidural hematoma, 2 for deep surgical-site infections, and 3 for superficial surgical-site infections. Other complications included superficial wound dehiscence [8], dural tears [6], non-unions not requiring reoperation [2], lumbar radiculopathies [3], and perioperative medical complications [5].ConclusionsThis study demonstrates that modular pedicle screw fixation has reoperation rates similar to those previously reported for standard pedicle screws. There was no failure at the screw-head junction, and no increases in other complications. Modular pedicle screws present an excellent option to allow surgeons to place pedicle screws without the risk of extra complications.
Project description:IntroductionTransforaminal lumbar interbody fusion (TLIF) has been widely used in the treatment of lumbar degenerative disc disorders and shows favourable clinical results. Recently, cortical bone trajectory (CBT) has become a new trajectory for screw insertion in the lumbar spine. Several biomechanical studies have demonstrated that the CBT technique achieves screw purchase and strength greater than the traditional method. Currently, the available data on the clinical effectiveness of the two performed surgeries, TLIF with CBT screws (CBT-TLIF) and TLIF with traditional pedicle screws (PS-TLIF), are insufficient. This is the first randomised study to compare CBT-TLIF against traditional PS fixation and will provide recommendations for treating patients with lumbar degenerative disc disorders.Methods and analysisA blinded randomised controlled trial (blinding for the patient and statistician, rather than for the clinician and researcher) will be conducted. A total of 254 participants with lumbar disc degenerative disease who are candidates for TLIF surgery will be randomly allocated to either the CBT-TLIF group or the PS-TLIF group at a ratio of 1:1. The primary clinical outcome measures are the incidence of adjacent cranial facet joint violation, fusion rate and the screw loosening rate. Secondary clinical outcome measures are Visual Analogue Scale (VAS) of back pain, VAS of leg pain, Oswestry Disability Index, operative time, intraoperative blood loss and complications. These parameters will be evaluated on day 3, and then at 1, 3, 6, 12 and 24 months postoperatively.Ethics and disseminationThis study has been reviewed and approved by the Institutional Review Board of the Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University (batch: 2017-03). The results will be presented in peer-reviewed journals and an international spine-related meeting after completion of the study.Trial registration numberNCT03105167; Pre-results.
Project description:BackgroundThe combined anterior-posterior approach has shown good clinical outcomes for multilevel cervical diseases. This work describes the biomechanical advantage of cervical-pedicle-screw fixation over lateral-mass-screw fixation in combined anterior-posterior cases.MethodSeventy-six patients who received combined cervical surgery from June 2013 to December 2020 were included. The patients were divided into two groups: the lateral-mass-screw group (LMS) and the pedicle-screw group (PPS). Radiological outcomes were assessed with lateral cervical spine X-rays for evaluating sagittal alignment, subsidence, and bone remodeling.ResultsAt 1 year postoperatively, the numbers of patients whose C2-C7 cervical lordosis was less than 20 degrees decreased by more in the PPS group (p-value = 0.001). The amount of vertical-length change from immediately to 1 year postsurgery was less in the PPS group than in the LMS group (p-value = 0.030). The mean vertebral-body-width change was larger in the PPS group than in the LMS group during 3 months to 1 year postsurgery (p-value = 0.000).ConclusionsIn combined anterior-posterior cervical surgery cases, maintenance of cervical lordosis and protection of the vertebral body from subsidence were better with the pedicle-screw fixation. More bone remodeling occurred when using the pedicle-screw fixation method.
Project description:Background: Posterior long spinal fusion was the common procedure for adult spinal deformity (ASD). Although the application of sacropelvic fixation (SPF), the incidence of pseudoarthrosis and implant failure is still high in long spinal fusion extending to lumbosacral junction (LSJ). To address these mechanical complications, advanced SPF technique by multiple pelvic screws or multirod construct has been recommended. This was the first study to compare the biomechanical performance of combining multiple pelvic screws and multirod construct to other advanced SPF constructs for the augmentation of LSJ in long spinal fusion surgery through finite element (FE) analysis. Methods: An intact lumbopelvic FE model based on computed tomography images of a healthy adult male volunteer was constructed and validated. The intact model was modified to develop five instrumented models, all of which had bilateral pedicle screw (PS) fixation from L1 to S1 with posterior lumbar interbody fusion and different SPF constructs, including No-SPF, bilateral single S2-alar-iliac (S2AI) screw and single rod (SS-SR), bilateral multiple S2AI screws and single rod (MS-SR), bilateral single S2AI screw and multiple rods (SS-MR), and bilateral multiple S2AI screws and multiple rods (MS-MR). The range of motion (ROM) and stress on instrumentation, cages, sacrum, and S1 superior endplate (SEP) in flexion (FL), extension (EX), lateral bending (LB), and axial rotation (AR) were compared among models. Results: Compared with intact model and No-SPF, the ROM of global lumbopelvis, LSJ, and sacroiliac joint (SIJ) was decreased in SS-SR, MS-SR, SS-MR, and MS-MR in all directions. Compared with SS-SR, the ROM of global lumbopelvis and LSJ of MS-SR, SS-MR, and MS-MR further decreased, while the ROM of SIJ was only decreased in MS-SR and MS-MR. The stress on instrumentation, cages, S1-SEP, and sacrum decreased in SS-SR, compared with no-SPF. Compared with SS-SR, the stress in EX and AR further decreased in SS-MR and MS-SR. The most significantly decreased ROM and stress were observed in MS-MR. Conclusion: Both multiple pelvic screws and multirod construct could increase the mechanical stability of LSJ and reduce stress on instrumentation, cages, S1-SEP, and sacrum. The MS-MR construct was the most adequate to reduce the risk of lumbosacral pseudarthrosis, implant failure, and sacrum fracture. This study may provide surgeons with important evidence for the application of MS-MR construct in the clinical settings.
Project description:Short-segment instrumentation for spine fractures is threatened by relatively high failure rates. Failure of the spinal pedicle screws including breakage and loosening may jeopardize the fixation integrity and lead to treatment failure. Two important design objectives, bending strength and pullout strength, may conflict with each other and warrant a multiobjective optimization study. In the present study using the three-dimensional finite element (FE) analytical results based on an L25 orthogonal array, bending and pullout objective functions were developed by an artificial neural network (ANN) algorithm, and the trade-off solutions known as Pareto optima were explored by a genetic algorithm (GA). The results showed that the knee solutions of the Pareto fronts with both high bending and pullout strength ranged from 92% to 94% of their maxima, respectively. In mechanical validation, the results of mathematical analyses were closely related to those of experimental tests with a correlation coefficient of -0.91 for bending and 0.93 for pullout (P < 0.01 for both). The optimal design had significantly higher fatigue life (P < 0.01) and comparable pullout strength as compared with commercial screws. Multiobjective optimization study of spinal pedicle screws using the hybrid of ANN and GA could achieve an ideal with high bending and pullout performances simultaneously.
Project description:Background: In recent years, intraoperative computed tomography (CT) navigation has become widely used for the insertion of pedicle screws in spinal fusion surgery. However, conventional intraoperative CT navigation may be impaired by infrared interference between the infrared camera and surgical instruments, which can lead to the misplacement of pedicle screws. Recently, a novel intraoperative CT navigation system, NextAR, has been developed. It uses a small infrared camera mounted on surgical instruments within the surgical field. NextAR navigation can minimize the problem of infrared interference and be expected to improve the accuracy of pedicle screw placement. Methods: This study investigated the accuracy of pedicle screw insertion under NextAR navigation in spinal fusion surgery for lumbar degenerative diseases. The accuracy of pedicle screw placement was evaluated in 15 consecutive patients using a CT grading scale. Results: Screw perforation occurred in only 1 of the total 70 screws (1.4%). Specifically, there was one grade 1 perforation within 2 mm, but no perforations larger than 2 mm. There were no reoperations or neurological complications due to screw misplacement. Conclusions: NextAR navigation can provide high accuracy for pedicle screw insertion and help ensure safe spinal fusion surgery for lumbar degenerative diseases.
Project description:AimsOur team tested spinal cord fusion (SCF) using the neuroprotective agent polyethylene glycol (PEG) in different animal (mice, rats, and beagles) models with complete spinal cord transection. To further explore the application of SCF for the treatment of paraplegic patients, we developed a new clinical procedure for SCF called vascular pedicle hemisected spinal cord transplantation (vSCT) and tested this procedure in eight paraplegic participants.MethodsEight paraplegic participants (American Spinal Injury Association, ASIA: A) were enrolled and treated with vSCT (PEG was applied to the sites of spinal cord transplantation). Pre- and postoperative pain intensities, neurologic assessments, electrophysiologic monitoring, and neuroimaging examinations were recorded.ResultsOf the eight paraplegic participants who completed vSCT, objective improvements occurred in motor function for one participant, in electrophysiologic motor-evoked potentials for another participant, in re-establishment of white matter continuity in three participants, in autonomic nerve function in seven participants, and in symptoms of cord central pain for seven participants.ConclusionsThe postoperative recovery of paraplegic participants demonstrated the clinical feasibility and efficacy of vSCT in re-establishing the continuity of spinal nerve fibers. vSCT could provide the anatomic, morphologic, and histologic foundations to potentially restore the motor, sensory, and autonomic nervous functions in paraplegic patients. More future clinical trials are warranted.