Unknown

Dataset Information

Mechanical power ratio threshold for ventilator-induced lung injury.


ABSTRACT:

Rationale

Mechanical power (MP) is a summary variable incorporating all causes of ventilator-induced-lung-injury (VILI). We expressed MP as the ratio between observed and normal expected values (MPratio).

Objective

To define a threshold value of MPratio leading to the development of VILI.

Methods

In a population of 82 healthy pigs, a threshold of MPratio for VILI, as assessed by histological variables and confirmed by using unsupervised cluster analysis was 4.5. The population was divided into two groups with MPratio above or below the threshold.

Measurements and main results

We measured physiological variables every six hours. At the end of the experiment, we measured lung weight and wet-to-dry ratio to quantify edem

SUBMITTER: D'Albo R 

PROVIDER: S-EPMC11289208 | biostudies-literature | 2024 Jul

REPOSITORIES: biostudies-literature