ABSTRACT: High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) ionize and separate ions at reduced pressures of 10-40 mbar and over a wide range of reduced electric field strengths E/N of up to 120 Td. Their reduced operating pressure is distinct from that of conventional drift tube ion mobility spectrometers that operate at ambient pressure for trace compound detection. High E/N can lead to a field-induced fragmentation pattern that provides more specific structural information about the analytes. In addition, operation at high E/N values adds the field dependence of ion mobility as an additional separation dimension to low-field ion mobility, making interfering compounds less likely to cause a false positive alarm. In this work, we study the chemical warfare agents tabun (GA), sarin (GB), soman (GD), cyclosarin (GF) and sulfur mustard (HD) in a HiKE-IMS at variable E/N in both the reaction and the drift region. The results show that varying E/N can lead to specific fragmentation patterns at high E/N values combined with molecular signals at low E/N. Compared to the operation at a single E/N value in the drift region, the variation of E/N in the drift region also provides the analyte-specific field dependence of ion mobility as additional information. The accumulated data establish a unique fingerprint for each analyte that allows for reliable detection of chemical warfare agents even in the presence of interfering compounds with similar low-field ion mobilities, thus reducing false positives.

SUBMITTER: Schaefer C 

PROVIDER: S-EPMC11311216 | biostudies-literature | 2024 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reliable Detection of Chemical Warfare Agents Using High Kinetic Energy Ion Mobility Spectrometry.

Schaefer Christoph C   Allers Maria M   Hitzemann Moritz M   Nitschke Alexander A   Kobelt Tim T   Mörtel Max M   Schröder Stefanie S   Ficks Arne A   Zimmermann Stefan S  

Journal of the American Society for Mass Spectrometry 20240716 8


High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) ionize and separate ions at reduced pressures of 10-40 mbar and over a wide range of reduced electric field strengths <i>E</i>/<i>N</i> of up to 120 Td. Their reduced operating pressure is distinct from that of conventional drift tube ion mobility spectrometers that operate at ambient pressure for trace compound detection. High <i>E</i>/<i>N</i> can lead to a field-induced fragmentation pattern that provides more specific structural infor  ...[more]

Similar Datasets

| S-EPMC10666079 | biostudies-literature
| S-EPMC10326917 | biostudies-literature
| S-EPMC6289487 | biostudies-literature
| S-EPMC8518932 | biostudies-literature
| S-EPMC9797248 | biostudies-literature
| S-EPMC9440894 | biostudies-literature
| S-EPMC9511967 | biostudies-literature
| S-EPMC4184456 | biostudies-literature
| S-EPMC4744830 | biostudies-literature
| S-EPMC5533171 | biostudies-literature