Uncovering patterns of inhaler technique and reliever use: the value of objective, personalized data from a digital inhaler.


ABSTRACT: Electronic inhalers provide information about patterns of routine inhaler use. During a 12-week study, 360 asthma patients using albuterol Digihaler generated 53,083 inhaler events that were retrospectively analyzed. A total of 41,528 (78%) of the recorded inhalation events were suitable for flow analysis (having a PIF ≥ 18 L/min and <120 L/min). Median PIF, inhalation volume, inhalation duration, and time to PIF for these events steadily decreased between the first and last 10 days of the study, by 5.1%, 12.6%, 15.9%, and 6.4%, respectively. Continuous short-acting beta2-agonist (SABA) overuse, defined as ≥2 SABA inhalations/week throughout the study period, was seen in 29% (n = 104) of patients. Of 260 patients with ≥1 instance of acute short-term SABA overuse, 55 (21%) had a confirmed exacerbation. Electronic recording of real-life inhaler use can capture valuable, objective information that could inform disease management and clinical decision-making.

SUBMITTER: Levy ML 

PROVIDER: S-EPMC11336086 | biostudies-literature | 2024 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Uncovering patterns of inhaler technique and reliever use: the value of objective, personalized data from a digital inhaler.

Levy Mark L ML   Kocks Janwillem W H JWH   Bosnic-Anticevich Sinthia S   Safioti Guilherme G   Reich Michael M   Depietro Michael M   Castro Mario M   Farooqui Nabeel N   Lugogo Njira L NL   Brown Randall R   Hill Tanisha T   Li Thomas T   Chrystyn Henry H  

NPJ primary care respiratory medicine 20240820 1


Electronic inhalers provide information about patterns of routine inhaler use. During a 12-week study, 360 asthma patients using albuterol Digihaler generated 53,083 inhaler events that were retrospectively analyzed. A total of 41,528 (78%) of the recorded inhalation events were suitable for flow analysis (having a PIF ≥ 18 L/min and <120 L/min). Median PIF, inhalation volume, inhalation duration, and time to PIF for these events steadily decreased between the first and last 10 days of the study  ...[more]

Similar Datasets

| S-EPMC5794789 | biostudies-literature
| S-EPMC7672138 | biostudies-literature
| S-EPMC5434787 | biostudies-literature
| S-EPMC10304614 | biostudies-literature
| S-EPMC6473469 | biostudies-literature
| S-EPMC9581185 | biostudies-literature
| S-EPMC7276524 | biostudies-literature
| S-EPMC6625439 | biostudies-literature
| S-EPMC7918490 | biostudies-literature
| S-EPMC7980192 | biostudies-literature