Prognostic Value of Optic Nerve Sheath Diameters after Acute Ischemic Stroke According to Slice Thickness on Computed Tomography.
Ontology highlight
ABSTRACT: The optic nerve sheath diameter (ONSD) can predict intracranial pressure and outcomes in neurological disease, but it remains unclear whether a small ONSD can be accurately measured on routine CT images with a slice thickness of approximately 4-5 mm. We measured the ONSD and ONSD/eyeball transverse diameter (ETD) ratio on routine-slice (4 mm) and thin-slice (0.6-0.75 mm) brain CT images from initial scans of acute ischemic stroke (AIS) patients. ONSD-related variables, National Institutes of Health Stroke Scale (NIHSS) scores, and age were compared between good (modified Rankin Scale [mRS] ≤ 2) and poor (mRS > 2) outcomes at discharge. Among 155 patients, 38 had poor outcomes. The thin-slice ONSD was different between outcome groups (p = 0.047), while the routine-slice ONSD showed n
SUBMITTER: Lee HB
PROVIDER: S-EPMC11354098 | biostudies-literature | 2024 Aug
REPOSITORIES: biostudies-literature
ACCESS DATA