Development of diagnostic algorithm for Cushing's syndrome: a tertiary centre experience.


ABSTRACT:

Purpose

No consensus exists as the gold standard for Cushing's Syndrome (CS) screening. This study aimed to evaluate the diagnostic accuracy and utility of late-night salivary cortisol (LNSC) and cortisone (LNSE), overnight dexamethasone suppression test (ODST), and urinary free cortisol (UFC) in developing a screening algorithm for CS.

Methods

A retrospective, single-centre analysis on 93 adult patients referred to the Oxford Centre for Diabetes, Endocrinology, and Metabolism for CS evaluation (2017-2022). Data were analysed using binomial logistic regression and area under the receiver-operating curve (AUROC).

Results

Fifty-three patients were diagnosed with CS. LNSC (sensitivity 87.5%, specificity 64.9%, AUC 0.76), LNSE (sensitivity 72.4%, specificity 85.7%, AUC 0.

SUBMITTER: Efthymiadis A 

PROVIDER: S-EPMC11393038 | biostudies-literature | 2024 Oct