Unknown

Dataset Information

Dosimetric comparison of proton therapy and CyberKnife in stereotactic body radiation therapy for liver cancers.


ABSTRACT: Stereotactic body radiation therapy (SBRT) has been increasingly used for the ablation of liver tumours. CyberKnife and proton beam therapy (PBT) are two advanced treatment technologies suitable to deliver SBRT with high dose conformity and steep dose gradients. However, there is very limited data comparing the dosimetric characteristics of CyberKnife to PBT for liver SBRT. PBT and CyberKnife plans were retrospectively generated using 4DCT datasets of ten patients who were previously treated for hepatocellular carcinoma (HCC, N = 5) and liver metastasis (N = 5). Dose volume histogram data was assessed and compared against selected criteria; given a dose prescription of 54 Gy in 3 fractions for liver metastases and 45 Gy in 3 fractions for HCC, with previously published consensus-based norm

SUBMITTER: Shyllon S 

PROVIDER: S-EPMC11408538 | biostudies-literature | 2024 Sep

REPOSITORIES: biostudies-literature